Literature DB >> 2318787

Adaptation of the inert gas FRC technique for use in heavy exercise.

B D Johnson1, K C Seow, D F Pegelow, J A Dempsey.   

Abstract

We automated the inert gas rebreathe technique for measurement of end-expiratory lung volume (EELV) during heavy exercise. We also assessed the use of two gas tracers (He and N2) vs. a single gas tracer (He) for measurement of this lung volume and compared the two-tracer EELV to changes in the inspiratory capacity (defined with transpulmonary pressure) and shifts in the end-expiratory pressure from rest through heavy exercise. A computer program switched a pneumatic valve when flow crossed zero at end expiration and defined points in the He and N2 traces for calculation of EELV. An inherent delay of the rebreathing valve (50 ms) caused virtually no error at rest and during light exercise and an error of 74 +/- 9 ml in the EELV at peak inspiratory flow rates of 4 l/s. The measurement of EELV by the two gas tracers was closely correlated to the single-gas tracer measurement (r = 0.97) but was consistently higher (120 +/- 10 ml) than when He was used alone. This difference was accentuated with increased work rates (2-5% error in the EELV, rest to heavy exercise) and as rebreathe time increased (2-7% error in the EELV with rebreathe times of 5-20 s for all work loads combined). The double-gas tracer measurement of EELV agreed quite well with the thoracic gas volume at rest (P greater than 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2318787     DOI: 10.1152/jappl.1990.68.2.802

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  6 in total

1.  Inspiratory muscles do not limit maximal incremental exercise performance in healthy subjects.

Authors:  Lee M Romer; Jordan D Miller; Hans C Haverkamp; David F Pegelow; Jerome A Dempsey
Journal:  Respir Physiol Neurobiol       Date:  2006-11-10       Impact factor: 1.931

2.  Operating lung volumes are affected by exercise mode but not trunk and hip angle during maximal exercise.

Authors:  Joseph W Duke; Jonathon L Stickford; Joshua C Weavil; Robert F Chapman; Joel M Stager; Timothy D Mickleborough
Journal:  Eur J Appl Physiol       Date:  2014-08-02       Impact factor: 3.078

Review 3.  The pulmonary circulation and exercise responses in the elderly.

Authors:  Bryan J Taylor; Bruce D Johnson
Journal:  Semin Respir Crit Care Med       Date:  2010-10-12       Impact factor: 3.119

4.  Exercise-induced diaphragmatic fatigue in healthy humans.

Authors:  B D Johnson; M A Babcock; O E Suman; J A Dempsey
Journal:  J Physiol       Date:  1993-01       Impact factor: 5.182

5.  Inspiratory Capacity during Exercise: Measurement, Analysis, and Interpretation.

Authors:  Jordan A Guenette; Roberto C Chin; Julia M Cory; Katherine A Webb; Denis E O'Donnell
Journal:  Pulm Med       Date:  2013-02-07

6.  Assessing exercise limitation using cardiopulmonary exercise testing.

Authors:  Michael K Stickland; Scott J Butcher; Darcy D Marciniuk; Mohit Bhutani
Journal:  Pulm Med       Date:  2012-11-19
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.