Literature DB >> 23187785

Diagnostic possibilities of specific fibrin(ogen) degradation products in relation to venous thromboembolism.

Fred J L M Haas1, Roger E G Schutgens, Douwe H Biesma, Ria H Laterveer, Cornelis Kluft.   

Abstract

The exclusion of deep venous thrombosis (DVT) in the elderly is hampered by low specificity in clinical decision of D-dimer assays in older patients. To reduce false-positive results, we evaluated specific fibrin(ogen) degradation product assays for their contribution in the diagnosis of DVT. In a post-hoc study with outpatients suspected for DVT, we evaluated the elastase-specific fibrinogen (fibrinogen elastase degradation product, FgEDP) and D-E-specific fibrin (fibrin degradation product, FbDP) degradation product assays in relation to DVT. Results were combined with five D-dimer assays as ratio, with a specific focus on age-dependency. In 437 patients (DVT prevalence 39%), FgEDP correlated with D-dimer in DVT-negative patients (P<0.001), but not in DVT-positive patients (P > 0.55). FbDP results correlated with D-dimer in both groups (P<0.001). The values of the area under the curve of the receiver operating characteristic curve for both assays were lower than D-dimer. Using the ratios, only in the fourth age quartile D-dimer/FgEDP ratios had diagnostic value with lower number needed to test (1.8-12.7) as compared to D-dimer less than 500 μg/l alone (5.4-102). The D-dimer/FbDP ratios in DVT-negative elderly patients increased to a plateau by increasing D-dimer. In DVT-positive patients, these ratios were near constant for increasing values of D-dimer. In elderly patients, the D-dimer/FgEDP ratios may improve the number of patients in whom DVT could be excluded. The D-dimer/FbDP ratios showed differences in composition of fibrin degradation products between DVT-negative and DVT-positive patients and between young and old DVT-negative patients.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23187785     DOI: 10.1097/MBC.0b013e32835bdcbd

Source DB:  PubMed          Journal:  Blood Coagul Fibrinolysis        ISSN: 0957-5235            Impact factor:   1.276


  1 in total

1.  Clinical utility of the ratio between circulating fibrinogen and fibrin (ogen) degradation products for evaluating coronary artery disease in type 2 diabetic patients.

Authors:  Wei-Xin Xiong; Ying Shen; Dao-Peng Dai; Lin Lu; Qi Zhang; Rui-Yan Zhang; Wei-Feng Shen; Rong Tao
Journal:  Chin Med J (Engl)       Date:  2015-03-20       Impact factor: 2.628

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.