Literature DB >> 23187739

An electrochemical biosensor for 3-hydroxybutyrate detection based on screen-printed electrode modified by coenzyme functionalized carbon nanotubes.

Fahimeh Khorsand1, Maedeh Darziani Azizi, Ali Naeemy, Bagher Larijani, Kobra Omidfar.   

Abstract

3-Hydroxybutyrate, one of the main blood ketone bodies, has been considered as a critical indicator for diagnosis of diabetic ketoacidosis. Biosensors designed for detection of 3-hydroxybutyrate with advantages of precision, easiness and speedy performance have attracted increasing attention. This study attempted to develop a 3-hydroxybutyrate dehydrogenase-based biosensor in which single-walled carbon nanotubes (SWCNT) was used in order to immobilize the cofactor, NAD(+), on the surface of screen-printed electrode. The formation of NAD(+)-SWCNT conjugates was assessed by electrochemistry and electron microscopy. Cyclic voltammetry was used to analyze the performance of this biosensor electrochemically. The considerable shelf life and reliability of the proposed biosensor to analyze real sample was confirmed by this method. The reduction in the over potential of electrochemical oxidation of NADH to -0.15 V can be mentioned as a prominent feature of this biosensor. This biosensor can detect 3-hydroxybutyrate in the linear range of 0.01-0.1 mM with the low detection limit of 0.009 mM. Simultaneous application of screen-printed electrode and SWCNT has made the biosensor distinguished which can open new prospects for detection of other clinically significant metabolites.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23187739     DOI: 10.1007/s11033-012-2314-4

Source DB:  PubMed          Journal:  Mol Biol Rep        ISSN: 0301-4851            Impact factor:   2.316


  5 in total

1.  A Paper-Based "Pop-up" Electrochemical Device for Analysis of Beta-Hydroxybutyrate.

Authors:  Chien-Chung Wang; Jonathan W Hennek; Alar Ainla; Ashok A Kumar; Wen-Jie Lan; Judy Im; Barbara S Smith; Mengxia Zhao; George M Whitesides
Journal:  Anal Chem       Date:  2016-05-31       Impact factor: 6.986

Review 2.  Gold Nanoparticles for Diagnostics: Advances towards Points of Care.

Authors:  Mílton Cordeiro; Fábio Ferreira Carlos; Pedro Pedrosa; António Lopez; Pedro Viana Baptista
Journal:  Diagnostics (Basel)       Date:  2016-11-22

3.  An Electrochemical Enzyme Biosensor for 3-Hydroxybutyrate Detection Using Screen-Printed Electrodes Modified by Reduced Graphene Oxide and Thionine.

Authors:  Gonzalo Martínez-García; Elena Pérez-Julián; Lourdes Agüí; Naomí Cabré; Jorge Joven; Paloma Yáñez-Sedeño; José Manuel Pingarrón
Journal:  Biosensors (Basel)       Date:  2017-11-11

Review 4.  Point-of-care biosensors in medicine: a brief overview of our achievements in this field based on the conducted research in EMRI (endocrinology and metabolism research Institute of Tehran University of medical sciences) over the past fourteen years.

Authors:  Kobra Omidfar; Anita Ahmadi; Leila Syedmoradi; Seyyed Mehdi Khoshfetrat; Bagher Larijani
Journal:  J Diabetes Metab Disord       Date:  2020-10-28

Review 5.  An Overview of Functionalized Graphene Nanomaterials for Advanced Applications.

Authors:  Andrea Maio; Ivana Pibiri; Marco Morreale; Francesco Paolo La Mantia; Roberto Scaffaro
Journal:  Nanomaterials (Basel)       Date:  2021-06-29       Impact factor: 5.076

  5 in total