BACKGROUND: The aim of this study was to evaluate if tilting of the distal implant at different angulations (30° and 40°) with different cantilever lengths (4 mm and 12 mm) affects the stress and strain distribution in an 'all-on-four' situation.
METHODS: A completely edentulous mandible was modelled with four tapered implants placed within the interforaminal region to receive an all acrylic fixed prosthesis. The two posterior implants were tilted at an angle of 30° and 40°. The prosthesis cantilever was given two different variables of 4 mm and 12 mm. For all models, the equivalent von Mises stress and strain was analysed using three-dimensional finite element analysis.
RESULTS: Statistical significance (p < 0.05) was seen when a comparison was made for the stress developed on the implant and cortical bone between the 30° and 40° distally tilted posterior implants in both situations. No significance was seen in the trabecular bone and on the strain developed in these situations.
CONCLUSIONS: The study shows that increasing the tilt of the distal implants does not increase the stress significantly. It also shows that the architecture of the mandible plays a major role during treatment planning of a completely edentulous patient.
© 2012 Australian Dental Association.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23186568     DOI: 10.1111/adj.12002

Source DB:  PubMed          Journal:  Aust Dent J        ISSN: 0045-0421            Impact factor:   2.291


  7 in total

1.  Evaluation of immediately loaded mandibular four vertical versus tilted posterior implants supporting fixed detachable restorations without versus with posterior cantilevers.

Authors:  Latifa Abdallah Mohamed; Mohamed Moataz Khamis; Ahlam Mostafa El-Sharkawy; Rania Abdelaziz Fahmy
Journal:  Oral Maxillofac Surg       Date:  2021-08-29

Review 2.  Angulated implants: an alternative to bone augmentation and sinus lift procedure: systematic review.

Authors:  Nikhil Asawa; Nilesh Bulbule; Dilip Kakade; Riddhi Shah
Journal:  J Clin Diagn Res       Date:  2015-03-01

3.  Finite element analysis of the effect of framework materials at the bone-implant interface in the all-on-four implant system.

Authors:  Kasturi Chandrashekhar Kelkar; Vinaya Bhat; Chethan Hegde
Journal:  Dent Res J (Isfahan)       Date:  2021-02-23

4.  A finite element analysis to study the stress distribution on distal implants in an all-on-four situation in atrophic maxilla as affected by the tilt of the implants and varying cantilever lengths.

Authors:  Anju Kumari; Puja Malhotra; Shefali Phogat; Bhupender Yadav; Jaiveer Yadav; Sumit Singh Phukela
Journal:  J Indian Prosthodont Soc       Date:  2020-10-08

5.  Comparison of stresses in monoblock tilted implants and conventional angled multiunit abutment-implant connection systems in the all-on-four procedure.

Authors:  Özge Özdal Zincir; Ateş Parlar
Journal:  BMC Oral Health       Date:  2021-12-16       Impact factor: 2.757

6.  Patterns of stress and strain in complete-arch prostheses supported by four or six implants: A literature review of finite element analyses.

Authors:  Nasrin Keshavarz Valian; Mohammad Reza Talebi Ardakani; Alireza Aziz Ahari; Mohammad Taghi Baghani; Shireen Shidfar
Journal:  J Adv Periodontol Implant Dent       Date:  2018-12-25

7.  Influence of Framework Material and Posterior Implant Angulation in Full-Arch All-on-4 Implant-Supported Prosthesis Stress Concentration.

Authors:  João Paulo Mendes Tribst; Dayana Campanelli de Morais; Jefferson David Melo de Matos; Guilherme da Rocha Scalzer Lopes; Amanda Maria de Oliveira Dal Piva; Alexandre Luiz Souto Borges; Marco Antonio Bottino; Antonio Lanzotti; Massimo Martorelli; Pietro Ausiello
Journal:  Dent J (Basel)       Date:  2022-01-14
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.