Literature DB >> 23185954

Evaluation of the performance of a motion capture system for small displacement recording and a discussion for its application potential in bone deformation in vivo measurements.

Peng-Fei Yang1, Maximilian Sanno, Gert-Peter Brüggemann, Jörn Rittweger.   

Abstract

The aim of this study is to evaluate the performance of a motion capture system and discuss the application potential of the proposed system in in vivo bone-segment deformation measurements. In this study, the effects of the calibration procedure, camera distance and marker size on the accuracy and precision of the motion capture system have been investigated by comparing the captured movement of the markers with reference movement. The results indicated that the system resolution is at least 20 microm in a capture volume of 400 X 300 X 300 mm3, which mostly covers the range of motion of the tibia during the stance phase of one gait cycle. Within this volume, the system accuracy and precision decreased following the increase of camera distance along the optical axis of the cameras. With the best configuration, the absolute error and precision for the range of 20 microm displacement were 1.2-1.8 microm and 1.5-2.5 microm, respectively. Small markers (Ø3-8 mm) yielded better accuracy and repeatability than the larger marker (Ø10.5 mm). We conclude that the proposed system is capable of recording minor displacements in a relative large volume.

Entities:  

Mesh:

Year:  2012        PMID: 23185954     DOI: 10.1177/0954411912452994

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  6 in total

1.  Reconstruction and positional accuracy of 3D ultrasound on vertebral phantoms for adolescent idiopathic scoliosis spinal surgery.

Authors:  Andrew Chan; Eric Parent; Edmond Lou
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-12-05       Impact factor: 2.924

2.  Detection and Classification of Artifact Distortions in Optical Motion Capture Sequences.

Authors:  Przemysław Skurowski; Magdalena Pawlyta
Journal:  Sensors (Basel)       Date:  2022-05-27       Impact factor: 3.847

3.  Analysis of the independent power of age-related, anthropometric and mechanical factors as determinants of the structure of radius and tibia in normal adults. A pQCT study.

Authors:  P Reina; G R Cointry; L Nocciolino; S Feldman; J L Ferretti; J Rittweger; R F Capozza
Journal:  J Musculoskelet Neuronal Interact       Date:  2015-03       Impact factor: 2.041

4.  A Study of Vicon System Positioning Performance.

Authors:  Pierre Merriaux; Yohan Dupuis; Rémi Boutteau; Pascal Vasseur; Xavier Savatier
Journal:  Sensors (Basel)       Date:  2017-07-07       Impact factor: 3.576

5.  On the Noise Complexity in an Optical Motion Capture Facility.

Authors:  Przemysław Skurowski; Magdalena Pawlyta
Journal:  Sensors (Basel)       Date:  2019-10-13       Impact factor: 3.576

6.  Torsion and antero-posterior bending in the in vivo human tibia loading regimes during walking and running.

Authors:  Peng-Fei Yang; Maximilian Sanno; Bergita Ganse; Timmo Koy; Gert-Peter Brüggemann; Lars Peter Müller; Jörn Rittweger
Journal:  PLoS One       Date:  2014-04-14       Impact factor: 3.240

  6 in total