Literature DB >> 23182889

Implantable Doppler in monitoring free flaps: a cost-effectiveness analysis based on a systematic review of the literature.

T G Poder1, P-H Fortier.   

Abstract

OBJECTIVE: The purpose of this paper is to evaluate the efficacy and cost-effectiveness of the implantable Doppler system based on the analysis of the available scientific literature and clinical and cost data available in our hospital. The results of this system are compared to those of conventional free flap monitoring methods.
MATERIALS AND METHODS: The literature published between 1991 and 2011 was systematically reviewed. All available cost data were collected and several simulations were performed. A retrospective assessment of the efficacy of conventional methods in our hospital was also conducted. RESULTS AND
CONCLUSION: The implantable Doppler system is more effective than the conventional methods used to monitor free flap perfusion. The mean flap salvage rate with the implantable Doppler was 21 percentage points higher (81.4 vs. 60.4). The excess cost compared to conventional methods was about CAD 120 per patient (about EUR 94). However, this excess cost can be compensated or even reversed, depending on the initial flap salvage rate in the health facility and the type of free flap (buried vs. non-buried).
Copyright © 2012 Elsevier Masson SAS. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23182889     DOI: 10.1016/j.anorl.2012.07.003

Source DB:  PubMed          Journal:  Eur Ann Otorhinolaryngol Head Neck Dis        ISSN: 1879-7296            Impact factor:   2.080


  9 in total

Review 1.  Postoperative Free-Flap Monitoring Techniques.

Authors:  Scott Kohlert; Alexandra E Quimby; Masoud Saman; Yadranko Ducic
Journal:  Semin Plast Surg       Date:  2019-03-08       Impact factor: 2.314

2.  Postoperative monitoring of free flap reconstruction: A comparison of external Doppler ultrasonography and the implantable Doppler probe.

Authors:  Rayaad C Hosein; Agustin Cornejo; Howard T Wang
Journal:  Plast Surg (Oakv)       Date:  2016       Impact factor: 0.947

Review 3.  Postoperative monitoring of the free jejunal flap: use of colour duplex and systematic review of available techniques.

Authors:  R Cuthbert; C Deutsch; A Roy; P Stimpson; H Patel
Journal:  Ann R Coll Surg Engl       Date:  2018-03-15       Impact factor: 1.891

4.  Intraoperative Utility of the Implantable Doppler in Lower Extremity Reconstruction: A Matched Case-control Study.

Authors:  Salma A Abdou; Banafsheh Sharif-Askary; Elizabeth G Zolper; Karen K Evans
Journal:  Plast Reconstr Surg Glob Open       Date:  2020-11-25

5.  Implantable Doppler Probes for Postoperatively Monitoring Free Flaps: Efficacy. A Systematic Review and Meta-analysis.

Authors:  Tzu-Yen Chang; Yao-Chou Lee; You-Cheng Lin; Stanley Thian-Sze Wong; Yuan-Yu Hsueh; Yao-Lung Kuo; Shyh-Jou Shieh; Jing-Wei Lee
Journal:  Plast Reconstr Surg Glob Open       Date:  2016-11-28

6.  Use of Near-infrared Spectroscopy and Implantable Doppler for Postoperative Monitoring of Free Tissue Transfer for Breast Reconstruction: A Systematic Review and Meta-analysis.

Authors:  Melissa Berthelot; James Ashcroft; Piers Boshier; Judith Hunter; Francis Patrick Henry; Benny Lo; Guang-Zhong Yang; Daniel Leff
Journal:  Plast Reconstr Surg Glob Open       Date:  2019-10-29

7.  Postoperative care in ICU versus non-ICU after head and neck free-flap surgery: a systematic review and meta-analysis.

Authors:  Mubarak Ahmed Mashrah; Linhu Ge; Taghrid Aldhohrah; Ahmed Abdelrehem; Bahia Sabri; Hyat Ahmed; Natheer H Al-Rawi; Tian Yu; Shiyong Zhao; Liping Wang
Journal:  BMJ Open       Date:  2022-01-06       Impact factor: 2.692

8.  The efficacy of the Cook-Swartz implantable Doppler in the detection of free-flap compromise: a systematic review protocol.

Authors:  Riaz A Agha; Buket Gundogan; Alexander J Fowler; Thomas W H Bragg; Dennis P Orgill
Journal:  BMJ Open       Date:  2014-03-12       Impact factor: 2.692

9.  Free Flap Anastomosis Leak after Implantable Doppler Removal.

Authors:  Véronique Anctil; Simon Brisebois; Pierre-Hugues Fortier
Journal:  OTO Open       Date:  2017-03-15
  9 in total