Effect of epicardial patch electrodes on transthoracic defibrillation.

B B Lerman1, O C Deale.   

Abstract

To improve survival rates in patients undergoing surgical ablative procedures for malignant ventricular tachycardia (VT), a frequent practice is to implant epicardial patch electrodes at the time of map-guided surgery. After operation, patients with inducible VT often receive an automatic internal cardioverter/defibrillator (AICD) implant, whereas patients with noninducible VT usually do not. In the event that spontaneous, hypotensive VT or ventricular fibrillation should subsequently occur in the patient with noninducible VT, however, transthoracic defibrillation and resuscitation may prove difficult, because the patch electrodes are insulated with silicone rubber that can reduce the amount of current traversing the myocardium and thus can increase transthoracic defibrillation threshold (DFT). In this study, DFT was determined in mongrel dogs to test the hypothesis that epicardial patch electrodes elevate threshold. This study was also designed to assess the effect of patch electrode orientation and size on DFT. In the first protocol (perpendicular orientation), small epicardial patch electrodes (surface area, 30 cm2) were sutured to the epicardial surfaces of the anterior right and posterior left ventricles in 15 dogs so that the center axes of the patch electrodes were coincident and perpendicular to the coincident center axes of the transthoracic electrodes. The effect of two large epicardial patch electrodes (surface area, 53 cm2) on transthoracic DFT was also examined in eight of these dogs. In the second protocol (parallel orientation), small patch electrodes were sutured to the lateral surfaces of the right and left ventricles in seven dogs.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1990        PMID: 2317917     DOI: 10.1161/01.cir.81.4.1409

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  2 in total

1.  Stimulatory current at the edge of an inactive conductor in an electric field: role of nonlinear interfacial current-voltage relationship.

Authors:  Jared A Sims; Andrew E Pollard; Peter S White; Stephen B Knisley
Journal:  IEEE Trans Biomed Eng       Date:  2009-07-14       Impact factor: 4.538

2.  Epicardial conductors can lower the defibrillation threshold in rabbit hearts.

Authors:  Jared A Sims; Stephen B Knisley Ast
Journal:  IEEE Trans Biomed Eng       Date:  2008-10-21       Impact factor: 4.538

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.