Validation of the Legipid bioalarm Legionella assay.

Guillermo Rodríguez Albalat1, Begoña Bedrina Broch, Marisa Jiménez Bono.   

Abstract

Legipid Bioalarm Legionella is a test based on combined magnetic immunocapture and enzyme-immunoassay (CEIA) for the detection of Legionella pneumophila in water. Anti-L. pneumophila antibodies are immobilized on magnetic microspheres. Immunomagnetic analysis is applied to preconcentrated water samples in a final test volume of 9 mL. The method was compared with the standard culture method on both spiked and naturally contaminated water samples. The test was evaluated in potable, industrial, and natural water matrixes, according to the scope of the ISO 11731 reference method. These waters were tested with the target at levels ranging from low (10-99 CFU/mL) to high (100-999 CFU/mL); a Chi-square value of 1.8 indicated that there was no significant difference between the test and the reference method. The false-positive rate was 7%, and the false-negative rate 2%. For the inclusivity study, all 17 strains of L. pneumophila of different serogroups reacted with the test. For the exclusivity study, 17 strains of other Legionella species and 16 non-Legionella strains were tested. There were no cross-reactions with non-Legionella strains. L. beliardensis, L. adelaidensis, and one environmentally isolated Legionella sp. produced a positive result at high concentrations of 1800, 230, and 3900 CFU/mL, respectively. Agreement between the two methods was 95.9%.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23175978     DOI: 10.5740/jaoacint.12-146

Source DB:  PubMed          Journal:  J AOAC Int        ISSN: 1060-3271            Impact factor:   1.913


  3 in total

Review 1.  Current and emerging Legionella diagnostics for laboratory and outbreak investigations.

Authors:  Jeffrey W Mercante; Jonas M Winchell
Journal:  Clin Microbiol Rev       Date:  2015-01       Impact factor: 26.132

2.  Comparing methods of determining Legionella spp. in complex water matrices.

Authors:  Álvaro Díaz-Flores; Juan Carlos Montero; Francisco Javier Castro; Eva María Alejandres; Carmen Bayón; Inmaculada Solís; Roberto Fernández-Lafuente; Guillermo Rodríguez
Journal:  BMC Microbiol       Date:  2015-04-29       Impact factor: 3.605

3.  Fast immunosensing technique to detect Legionella pneumophila in different natural and anthropogenic environments: comparative and collaborative trials.

Authors:  Begoña Bedrina; Sonia Macián; Inmaculada Solís; Roberto Fernández-Lafuente; Eva Baldrich; Guillermo Rodríguez
Journal:  BMC Microbiol       Date:  2013-04-22       Impact factor: 3.605

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.