Stress dissipation in the bone through various crown materials of dental implant restoration: a 2-D finite element analysis.

Supriya Bijjargi1, Ramesh Chowdhary.   

Abstract

AIM: To investigate stress transmitted by various restorative materials given for a full veneered implant-supported crown through implants in the bone.
METHODS: A 2-D finite element model of dental implant with an abutment and full crown was designed. The materials used for stress dissipation were zirconia, full ceramic, full metal crown, composite crown, and acrylic crown. Adequate boundary conditions were applied, as was a vertical load of 100 N.
RESULTS: The highest stress value was exhibited for the zirconia prosthesis model, and maximum stress dissipation for the same model was observed around the cervical region of the abutment and abutment-implant junction (24.877 Mpa).
CONCLUSION: Within the limitations of this study, it was concluded that an occlusal material with a low modulus of elasticity, such as acrylic resin, dampens the occlusal impact forces, thereby decreasing its effect on the bone-implant interface.
© 2012 Wiley Publishing Asia Pty Ltd.

Entities:  

Keywords:  composite crown; finite element analysis; implant restoration; stress dissipation; zirconia

Mesh:

Substances:

Year:  2012        PMID: 23172842     DOI: 10.1111/j.2041-1626.2012.00149.x

Source DB:  PubMed          Journal:  J Investig Clin Dent        ISSN: 2041-1618


  4 in total

1.  In-vitro performance of CAD/CAM-fabricated implant-supported temporary crowns.

Authors:  Martin Rosentritt; Philipp Raab; Sebastian Hahnel; Matthias Stöckle; Verena Preis
Journal:  Clin Oral Investig       Date:  2017-01-21       Impact factor: 3.573

2.  In vitro performance and fracture resistance of CAD/CAM-fabricated implant supported molar crowns.

Authors:  Martin Rosentritt; Sebastian Hahnel; Frank Engelhardt; Michael Behr; Verena Preis
Journal:  Clin Oral Investig       Date:  2016-07-01       Impact factor: 3.573

3.  A Systematic Study of Restorative Crown-Materials Combinations for Dental Implants: Characterization of Mechanical Properties under Dynamic Loads.

Authors:  Xavier Marimon; Miguel Cerrolaza; Miquel Ferrer; Oriol Cantó-Navés; Josep Cabratosa-Termes; Román Pérez
Journal:  Int J Mol Sci       Date:  2022-08-07       Impact factor: 6.208

4.  Full-zirconia single-tooth molar implant-supported restorations with angulated screw channel abutments: A 1-year prospective case series study.

Authors:  Christiaan W P Pol; Gerry M Raghoebar; Zakelina Maragkou; Marco S Cune; Henny J A Meijer
Journal:  Clin Implant Dent Relat Res       Date:  2019-12-03       Impact factor: 3.932

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.