Literature DB >> 23169010

Kinetic modeling of hyperpolarized (13)C pyruvate metabolism in tumors using a measured arterial input function.

S M Kazan1, S Reynolds, A Kennerley, E Wholey, J E Bluff, J Berwick, V J Cunningham, M N Paley, G M Tozer.   

Abstract

Mathematical models are required to estimate kinetic parameters of [1-(13)C] pyruvate-lactate interconversion from magnetic resonance spectroscopy data. One- or two-way exchange models utilizing a hypothetical approximation to the true arterial input function (AIF), (e.g. an ideal 'box-car' function) have been used previously. We present a method for direct measurement of the AIF in the rat. The hyperpolarized [1-(13)C] pyruvate signal was measured in arterial blood as it was continuously withdrawn through a small chamber. The measured signal was corrected for T1 relaxation of pyruvate, RF pulses and dispersion of blood in the chamber to allow for the estimation of the direct AIF. Using direct AIF, rather than the commonly used box-car AIF, provided realistic estimates of the rate constant of conversion of pyruvate to lactate, kpl, the rate constant of conversion of lactate to pyruvate klp, the clearance rate constant of pyruvate from blood to tissue, Kip, and the relaxation rate of lactate T1la. Since no lactate signal was present in blood, it was possible to use a simple precursor-product relationship, with the tumor tissue pyruvate time-course as the input for the lactate time-course. This provided a robust estimate of kpl, similar to that obtained using a directly measured AIF.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Keywords:  arterial input function; dynamic nuclear polarization; hyperpolarization; kinetic modeling

Mesh:

Substances:

Year:  2012        PMID: 23169010     DOI: 10.1002/mrm.24546

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  26 in total

1.  A novel perfused Bloch-McConnell simulator for analyzing the accuracy of dynamic hyperpolarized MRS.

Authors:  Christopher M Walker; Yunyun Chen; Stephen Y Lai; James A Bankson
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

2.  A 2DRF pulse sequence for bolus tracking in hyperpolarized 13C imaging.

Authors:  Shuyu Tang; Wenwen Jiang; Hsin-Yu Chen; Robert Bok; Daniel B Vigneron; Peder E Z Larson
Journal:  Magn Reson Med       Date:  2014-08-22       Impact factor: 4.668

3.  Non-invasive in vivo assessment of IDH1 mutational status in glioma.

Authors:  Myriam M Chaumeil; Peder E Z Larson; Hikari A I Yoshihara; Olivia M Danforth; Daniel B Vigneron; Sarah J Nelson; Russell O Pieper; Joanna J Phillips; Sabrina M Ronen
Journal:  Nat Commun       Date:  2013       Impact factor: 14.919

4.  The effect of exogenous substrate concentrations on true and apparent metabolism of hyperpolarized pyruvate in the isolated perfused lung.

Authors:  Stephen Kadlecek; Hoora Shaghaghi; Sarmad Siddiqui; Harrilla Profka; Mehrdad Pourfathi; Rahim Rizi
Journal:  NMR Biomed       Date:  2014-10-20       Impact factor: 4.044

5.  Assessing Prostate Cancer Aggressiveness with Hyperpolarized Dual-Agent 3D Dynamic Imaging of Metabolism and Perfusion.

Authors:  Hsin-Yu Chen; Peder E Z Larson; Robert A Bok; Cornelius von Morze; Renuka Sriram; Romelyn Delos Santos; Justin Delos Santos; Jeremy W Gordon; Naeim Bahrami; Marcus Ferrone; John Kurhanewicz; Daniel B Vigneron
Journal:  Cancer Res       Date:  2017-04-20       Impact factor: 12.701

6.  Optimizing Flip Angles for Metabolic Rate Estimation in Hyperpolarized Carbon-13 MRI.

Authors:  John Maidens; Jeremy W Gordon; Murat Arcak; Peder E Z Larson
Journal:  IEEE Trans Med Imaging       Date:  2016-05-27       Impact factor: 10.048

7.  Kinetic Modeling of Hyperpolarized Carbon-13 Pyruvate Metabolism in the Human Brain.

Authors:  Daniele Mammoli; Jeremy Gordon; Adam Autry; Peder E Z Larson; Yan Li; Hsin-Yu Chen; Brian Chung; Peter Shin; Mark Van Criekinge; Lucas Carvajal; James B Slater; Robert Bok; Jason Crane; Duan Xu; Susan Chang; Daniel B Vigneron
Journal:  IEEE Trans Med Imaging       Date:  2019-07-02       Impact factor: 10.048

8.  Kinetic Modeling and Constrained Reconstruction of Hyperpolarized [1-13C]-Pyruvate Offers Improved Metabolic Imaging of Tumors.

Authors:  James A Bankson; Christopher M Walker; Marc S Ramirez; Wolfgang Stefan; David Fuentes; Matthew E Merritt; Jaehyuk Lee; Vlad C Sandulache; Yunyun Chen; Liem Phan; Ping-Chieh Chou; Arvind Rao; Sai-Ching J Yeung; Mong-Hong Lee; Dawid Schellingerhout; Charles A Conrad; Craig Malloy; A Dean Sherry; Stephen Y Lai; John D Hazle
Journal:  Cancer Res       Date:  2015-09-29       Impact factor: 12.701

9.  Kinetic Analysis of Hepatic Metabolism Using Hyperpolarized Dihydroxyacetone.

Authors:  Alexander Kirpich; Mukundan Ragavan; James A Bankson; Lauren M McIntyre; Matthew E Merritt
Journal:  J Chem Inf Model       Date:  2019-01-15       Impact factor: 4.956

10.  A regional bolus tracking and real-time B1 calibration method for hyperpolarized 13 C MRI.

Authors:  Shuyu Tang; Eugene Milshteyn; Galen Reed; Jeremy Gordon; Robert Bok; Xucheng Zhu; Zihan Zhu; Daniel B Vigneron; Peder E Z Larson
Journal:  Magn Reson Med       Date:  2018-09-18       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.