Literature DB >> 23168945

Multislice cardiac arterial spin labeling using improved myocardial perfusion quantification with simultaneously measured blood pool input function.

Adrienne E Campbell-Washburn1, Hui Zhang, Bernard M Siow, Anthony N Price, Mark F Lythgoe, Roger J Ordidge, David L Thomas.   

Abstract

PURPOSE: Myocardial blood flow (MBF) is an important indicator of cardiac tissue health, which can be measured using arterial spin labeling. This study aimed to develop a new method of MBF quantification with blood pool magnetization measurement ("bpMBF quantification") that allows multislice cardiac arterial spin labeling. THEORY AND METHODS: A multislice segmented ECG-gated Look-Locker T1 mapping sequence was validated. Quantification of multislice arterial spin labeling is not straightforward due to the large volume of blood inverted following slice-selective inversion. For bpMBF quantification, a direct measurement of the left-ventricle blood pool magnetization was used to approximate the blood input function into the Bloch equations. Simulations and in vivo measurements in the mouse heart were performed to evaluate the bpMBF method.
RESULTS: Measurements indicated that blood pool magnetization requires ∼3 s to return to equilibrium following slice-selective inversion. Simulation and in vivo results show that bpMBF quantification is robust to variations in slice-selective thickness and therefore applicable to multislice acquisition, whereas traditional methods are likely to underestimate multislice perfusion. In vivo, single and multislice perfusion values matched well when quantified using bpMBF.
CONCLUSION: The first multislice cardiac arterial spin labeling technique has been presented, which can be used for accurate perfusion measurements in studies of cardiac disease.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Keywords:  arterial spin labeling; cardiac; look‐locker; multislice; perfusion; perfusion model

Mesh:

Substances:

Year:  2012        PMID: 23168945     DOI: 10.1002/mrm.24545

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  8 in total

1.  Accelerated dual-contrast first-pass perfusion MRI of the mouse heart: development and application to diet-induced obese mice.

Authors:  Nivedita K Naresh; Xiao Chen; Rene J Roy; Patrick F Antkowiak; Brian H Annex; Frederick H Epstein
Journal:  Magn Reson Med       Date:  2014-04-23       Impact factor: 4.668

2.  Investigating Low-Velocity Fluid Flow in Tumors with Convection-MRI.

Authors:  Simon Walker-Samuel; Thomas A Roberts; Rajiv Ramasawmy; Jake S Burrell; Sean Peter Johnson; Bernard M Siow; Simon Richardson; Miguel R Gonçalves; Douglas Pendse; Simon P Robinson; R Barbara Pedley; Mark F Lythgoe
Journal:  Cancer Res       Date:  2018-01-09       Impact factor: 12.701

3.  Hepatic arterial spin labelling MRI: an initial evaluation in mice.

Authors:  R Ramasawmy; A E Campbell-Washburn; J A Wells; S P Johnson; R B Pedley; S Walker-Samuel; M F Lythgoe
Journal:  NMR Biomed       Date:  2014-12-17       Impact factor: 4.044

4.  Quantifying the area-at-risk of myocardial infarction in-vivo using arterial spin labeling cardiac magnetic resonance.

Authors:  Rachel K Dongworth; Adrienne E Campbell-Washburn; Hector A Cabrera-Fuentes; Heerajnarain Bulluck; Thomas Roberts; Anthony N Price; Sauri Hernández-Reséndiz; Roger J Ordidge; David L Thomas; Derek M Yellon; Mark F Lythgoe; Derek J Hausenloy
Journal:  Sci Rep       Date:  2017-05-23       Impact factor: 4.379

Review 5.  Myocardial arterial spin labeling.

Authors:  Frank Kober; Terrence Jao; Thomas Troalen; Krishna S Nayak
Journal:  J Cardiovasc Magn Reson       Date:  2016-04-12       Impact factor: 5.364

6.  Time course of cardiometabolic alterations in a high fat high sucrose diet mice model and improvement after GLP-1 analog treatment using multimodal cardiovascular magnetic resonance.

Authors:  Inès Abdesselam; Pauline Pepino; Thomas Troalen; Michael Macia; Patricia Ancel; Brice Masi; Natacha Fourny; Bénédicte Gaborit; Benoît Giannesini; Frank Kober; Anne Dutour; Monique Bernard
Journal:  J Cardiovasc Magn Reson       Date:  2015-11-06       Impact factor: 5.364

7.  Non-contrast assessment of microvascular integrity using arterial spin labeled cardiovascular magnetic resonance in a porcine model of acute myocardial infarction.

Authors:  Hung P Do; Venkat Ramanan; Xiuling Qi; Jennifer Barry; Graham A Wright; Nilesh R Ghugre; Krishna S Nayak
Journal:  J Cardiovasc Magn Reson       Date:  2018-07-02       Impact factor: 5.364

8.  Acute changes in liver tumour perfusion measured non-invasively with arterial spin labelling.

Authors:  S Peter Johnson; Rajiv Ramasawmy; Adrienne E Campbell-Washburn; Jack A Wells; Mathew Robson; Vineeth Rajkumar; Mark F Lythgoe; R Barbara Pedley; Simon Walker-Samuel
Journal:  Br J Cancer       Date:  2016-03-31       Impact factor: 7.640

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.