Force and torque modelling of drilling simulation for orthopaedic surgery.

Troy MacAvelia1, Ahmad Ghasempoor, Farrokh Janabi-Sharifi.   

Abstract

The advent of haptic simulation systems for orthopaedic surgery procedures has provided surgeons with an excellent tool for training and preoperative planning purposes. This is especially true for procedures involving the drilling of bone, which require a great amount of adroitness and experience due to difficulties arising from vibration and drill bit breakage. One of the potential difficulties with the drilling of bone is the lack of consistent material evacuation from the drill's flutes as the material tends to clog. This clogging leads to significant increases in force and torque experienced by the surgeon. Clogging was observed for feed rates greater than 0.5 mm/s and spindle speeds less than 2500 rpm. The drilling simulation systems that have been created to date do not address the issue of drill flute clogging. This paper presents force and torque prediction models that account for this phenomenon. The two coefficients of friction required by these models were determined via a set of calibration experiments. The accuracy of both models was evaluated by an additional set of validation experiments resulting in average R² regression correlation values of 0.9546 and 0.9209 for the force and torque prediction models, respectively. The resulting models can be adopted by haptic simulation systems to provide a more realistic tactile output.

Entities:  

Keywords:  bone drilling; drilling force and torque computation; haptic simulation; orthopaedic surgery

Mesh:

Year:  2012        PMID: 23167723     DOI: 10.1080/10255842.2012.739163

Source DB:  PubMed          Journal:  Comput Methods Biomech Biomed Engin        ISSN: 1025-5842            Impact factor:   1.763


  4 in total

1.  Template-guided vs. non-guided drilling in site preparation of dental implants.

Authors:  Uta Scherer; Marcus Stoetzer; Martin Ruecker; Nils-Claudius Gellrich; Constantin von See
Journal:  Clin Oral Investig       Date:  2014-10-30       Impact factor: 3.573

2.  Evaluation of accuracy in implant site preparation performed in single- or multi-step drilling procedures.

Authors:  Nadine Marheineke; Uta Scherer; Martin Rücker; Constantin von See; Björn Rahlf; Nils-Claudius Gellrich; Marcus Stoetzer
Journal:  Clin Oral Investig       Date:  2017-12-17       Impact factor: 3.573

3.  Comparative Analysis of Cutting Forces, Torques, and Vibration in Drilling of Bovine, Porcine, and Artificial Femur Bone with Considerations for Robot Effector Stiffness.

Authors:  Oluseyi Adewale Orelaja; Xingsong Wang; Donghua Shen; Dauda Sh Ibrahim; Tianzheng Zhao; Umer Sharif; Ishola A Afiz
Journal:  J Healthc Eng       Date:  2020-10-19       Impact factor: 2.682

4.  Data-Driven Modeling and Rendering of Force Responses from Elastic Tool Deformation.

Authors:  Arsen Abdulali; Ruslan Rakhmatov; Tatyana Ogay; Seokhee Jeon
Journal:  Sensors (Basel)       Date:  2018-01-15       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.