Literature DB >> 2316651

Splanchnic and systemic hemodynamics in mice using a radioactive microsphere technique.

S K Sarin1, C Sabba, R J Groszmann.   

Abstract

Mice are commonly used for the study of human disease processes. However, techniques for measuring systemic and hepatic blood flow in mice have not been developed. We attempted the conventional technique of radiolabeled microsphere injection into the left ventricle, but difficulties were encountered, including unsuspected ventricular perforation and outflow obstruction in 68% of the animals. We therefore evaluated whether an injection into the carotid artery close to the aortic arch can fulfill the criteria (approximately or greater than 300 microspheres in femoral blood or tissues, adequate mixing of microspheres with blood, and no significant alteration of blood pressure during microsphere injection) required for accurate measurement of systemic and regional hemodynamics. Carotid artery injection resulted in adequate mixing and number of microspheres in tissues in 78 and 91% of the animals, respectively. Portal venous inflow was 1.8 +/- 0.3 ml.min-1.g liver tissue-1 and renal blood flow was 5.1 +/- 0.75 ml.min-1.g tissue-1. Compared per unit weight, these values are quite similar to those reported in rats. Cardiac output was 12.1 +/- 1.2 ml/min and cardiac index was 462 +/- 47 ml.min-1.kg body wt-1. The reliability of cardiac output determination is improved if whole body radioactivity is taken into account. Five of 22 animals had to be excluded because of either a low number of microspheres in tissues or inadequate mixing of microspheres with blood (shown by asymmetrical distribution of microspheres between left and right kidney). With modifications, the radioactive microsphere technique can be adapted to the hemodynamic study of mice.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2316651     DOI: 10.1152/ajpgi.1990.258.3.G365

Source DB:  PubMed          Journal:  Am J Physiol        ISSN: 0002-9513


  15 in total

Review 1.  Blood flow distributions by microsphere deposition methods.

Authors:  F W Prinzen; J B Bassingthwaighte
Journal:  Cardiovasc Res       Date:  2000-01-01       Impact factor: 10.787

2.  Organ-specific innate immune responses in a mouse model of invasive candidiasis.

Authors:  Michail S Lionakis; Jean K Lim; Chyi-Chia Richard Lee; Philip M Murphy
Journal:  J Innate Immun       Date:  2010-11-09       Impact factor: 7.349

Review 3.  Animal models of portal hypertension.

Authors:  Juan-G Abraldes; Marcos Pasarín; Juan-Carlos García-Pagán
Journal:  World J Gastroenterol       Date:  2006-11-07       Impact factor: 5.742

4.  Measuring bone blood supply in mice using fluorescent microspheres.

Authors:  Maria A Serrat
Journal:  Nat Protoc       Date:  2009-11-05       Impact factor: 13.491

5.  Effects of isoflurane anesthesia on the cardiovascular function of the C57BL/6 mouse.

Authors:  Christakis Constantinides; Richard Mean; Ben J Janssen
Journal:  ILAR J       Date:  2011

6.  Physiologically based pharmacokinetics of molecular imaging nanoparticles for mRNA detection determined in tumor-bearing mice.

Authors:  Armin W Opitz; Eric Wickstrom; Mathew L Thakur; Norman J Wagner
Journal:  Oligonucleotides       Date:  2010-06

7.  Propranolol ameliorates the development of portal-systemic shunting in a chronic murine schistosomiasis model of portal hypertension.

Authors:  S K Sarin; R J Groszmann; P G Mosca; M Rojkind; M J Stadecker; R Bhatnagar; A Reuben; Y Dayal
Journal:  J Clin Invest       Date:  1991-03       Impact factor: 14.808

8.  A modified fluorescent microsphere-based approach for determining resting and hyperemic blood flows in individual murine skeletal muscles.

Authors:  Trevor R Cardinal; James B Hoying
Journal:  Vascul Pharmacol       Date:  2007-04-19       Impact factor: 5.773

9.  Hepatic adaptation compensates inactivation of intestinal arginine biosynthesis in suckling mice.

Authors:  Vincent Marion; Selvakumari Sankaranarayanan; Chiel de Theije; Paul van Dijk; Theo B M Hakvoort; Wouter H Lamers; Eleonore S Köhler
Journal:  PLoS One       Date:  2013-06-13       Impact factor: 3.240

10.  A specialized microvascular domain in the mouse neural stem cell niche.

Authors:  James C Culver; Tegy J Vadakkan; Mary E Dickinson
Journal:  PLoS One       Date:  2013-01-07       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.