Literature DB >> 23160652

The impact of a phase-change cooling vest on heat strain and the effect of different cooling pack melting temperatures.

James R House1, Heather C Lunt, Rowan Taylor, Gemma Milligan, Jason A Lyons, Carol M House.   

Abstract

Cooling vests (CV) are often used to reduce heat strain. CVs have traditionally used ice as the coolant, although other phase-change materials (PCM) that melt at warmer temperatures have been used in an attempt to enhance cooling by avoiding vasoconstriction, which supposedly occurs when ice CVs are used. This study assessed the effectiveness of four CVs that melted at 0, 10, 20 and 30 °C (CV₀, CV₁₀, CV₂₀, and CV₃₀) when worn by 10 male volunteers exercising and then recovering in 40 °C air whilst wearing fire-fighting clothing. When compared with a non-cooling control condition (CON), only the CV₀ and CV₁₀ vests provided cooling during exercise (40 and 29 W, respectively), whereas all CVs provided cooling during resting recovery (CV₀ 69 W, CV₁₀ 66 W, CV₂₀ 55 W and CV₃₀ 29 W) (P < 0.05). In all conditions, skin blood flow increased when exercising and reduced during recovery, but was lower in the CV₀ and CV₁₀ conditions compared with control during exercise (observed power 0.709) (P < 0.05), but not during resting recovery (observed power only 0.55). The participants preferred the CV₁₀ to the CV₀, which caused temporary erythema to underlying skin, although this resolved overnight after each occurrence. Consequently, a cooling vest melting at 10 °C would seem to be the most appropriate choice for cooling during combined work and rest periods, although possibly an ice-vest (CV₀) may also be appropriate if more insulation was worn between the cooling packs and the skin than used in this study.

Entities:  

Mesh:

Year:  2012        PMID: 23160652     DOI: 10.1007/s00421-012-2534-2

Source DB:  PubMed          Journal:  Eur J Appl Physiol        ISSN: 1439-6319            Impact factor:   3.078


  22 in total

1.  Testing the effectiveness of techniques for reducing heat strain in Royal Navy nuclear, biological and chemical cleansing stations' teams.

Authors:  J R House; H Lunt; A Magness; J Lyons
Journal:  J R Nav Med Serv       Date:  2003

2.  A NEW WEIGHTING SYSTEM FOR MEAN SURFACE TEMPERATURE OF THE HUMAN BODY.

Authors:  N L RAMANATHAN
Journal:  J Appl Physiol       Date:  1964-05       Impact factor: 3.531

3.  Effects of warm-up and precooling on endurance performance in the heat.

Authors:  Sandra Uckert; Winfried Joch
Journal:  Br J Sports Med       Date:  2007-01-15       Impact factor: 13.800

4.  Warming up with an ice vest: core body temperature before and after cross-country racing.

Authors:  Iain Hunter; J Ty Hopkins; Douglas J Casa
Journal:  J Athl Train       Date:  2006 Oct-Dec       Impact factor: 2.860

5.  Cooling strategies improve intermittent sprint performance in the heat of athletes with tetraplegia.

Authors:  N Webborn; M J Price; P Castle; V L Goosey-Tolfrey
Journal:  Br J Sports Med       Date:  2008-06-14       Impact factor: 13.800

6.  Personal cooling with phase change materials to improve thermal comfort from a heat wave perspective.

Authors:  C Gao; K Kuklane; F Wang; I Holmér
Journal:  Indoor Air       Date:  2012-03-20       Impact factor: 5.770

7.  Mechanisms of control of skin blood flow during prolonged exercise in humans.

Authors:  D L Kellogg; J M Johnson; W L Kenney; P E Pérgola; W A Kosiba
Journal:  Am J Physiol       Date:  1993-08

8.  Heat strain reduction by ice-based and vapor compression liquid cooling systems with a toxic agent protective uniform.

Authors:  Bruce S Cadarette; Leslie Levine; Margaret A Kolka; Gary N Proulx; Mathew M Correa; Michael N Sawka
Journal:  Aviat Space Environ Med       Date:  2002-07

9.  Thermoregulatory influence of a cooling vest on hyperthermic athletes.

Authors:  Rebecca M Lopez; Michelle A Cleary; Leon C Jones; Ron E Zuri
Journal:  J Athl Train       Date:  2008 Jan-Mar       Impact factor: 2.860

10.  How should body heat storage be determined in humans: by thermometry or calorimetry?

Authors:  A L Vallerand; G Savourey; A M Hanniquet; J H Bittel
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1992
View more
  7 in total

1.  Effect of a cooling vest on core temperature in athletes with and without spinal cord injury.

Authors:  Michelle Trbovich; Catherine Ortega; James Schroeder; Mark Fredrickson
Journal:  Top Spinal Cord Inj Rehabil       Date:  2014

2.  An Ice Vest, but Not Single-Hand Cooling, Is Effective at Reducing Thermo-Physiological Strain During Exercise Recovery in the Heat.

Authors:  Afton D Seeley; Ross A Sherman
Journal:  Front Sports Act Living       Date:  2021-04-29

Review 3.  Occupational heat stress assessment and protective strategies in the context of climate change.

Authors:  Chuansi Gao; Kalev Kuklane; Per-Olof Östergren; Tord Kjellstrom
Journal:  Int J Biometeorol       Date:  2017-04-25       Impact factor: 3.787

4.  An Evaluation of Personal Cooling Systems for Reducing Thermal Strain Whilst Working in Chemical/Biological Protective Clothing.

Authors:  Aaron J E Bach; Matthew J Maley; Geoffrey M Minett; Stephanie A Zietek; Kelly L Stewart; Ian B Stewart
Journal:  Front Physiol       Date:  2019-04-12       Impact factor: 4.566

5.  A novel vest with dual functions for firefighters: combined effects of body cooling and cold fluid ingestion on the alleviation of heat strain.

Authors:  Do-Hyung Kim; Gyu-Tae Bae; Joo-Young Lee
Journal:  Ind Health       Date:  2019-06-29       Impact factor: 2.179

Review 6.  Don't Lose Your Cool With Cryotherapy: The Application of Phase Change Material for Prolonged Cooling in Athletic Recovery and Beyond.

Authors:  Susan Y Kwiecien; Malachy P McHugh; Glyn Howatson
Journal:  Front Sports Act Living       Date:  2020-10-15

7.  Optimizing the Use of Phase Change Material Vests Worn During Explosives Ordnance Disposal Operations in Hot Conditions.

Authors:  Sarah Lee Davey; Ben James Lee; Mark Smith; Mark Oldroyd; Charles Doug Thake
Journal:  Front Physiol       Date:  2020-10-29       Impact factor: 4.566

  7 in total