Effect of anterior-posterior and internal-external motion restraint during knee wear simulation on a posterior stabilised knee design.

Thomas M Grupp1, Khaled J Saleh, William M Mihalko, Martin Hintner, Bernhard Fritz, Christoph Schilling, Jens Schwiesau, Christian Kaddick.   

Abstract

The objective of our study was to examine the effect of biphaseal AP translation and IE rotation restraint, using a system defined specifically for posterior stabilised knee designs, on wear, kinematics and particle release in comparison to linear motion restraint as required by the established ISO 14243-1:2002(E) protocol. In the ISOlinear groups, an AP motion restraint of 30 N/mm and an IE rotation restraint of 0.6 Nm/° were applied in the knee wear simulation. In the ISOgap biphaseal groups with PCL sacrificing implants, the restraining AP force was zero in a ±2.5mm range with, externally, a constant of 9.3N/mm applied proportionally to the AP translation of the tibia plateau, whereas the restraining IE torque was zero in a ±6° range with, externally, a constant of 0.13 Nm/° applied proportionally to the IE rotation of the tibia plateau. Using the ISOgap biphaseal protocol on a posterior stabilised knee design, we found an increase of 41% in AP translation and of 131% in IE rotation, resulting in a 3.2-fold higher wear rate compared to the results obtained using the ISOlinear protocol. Changes in AP translation and IE rotation ligament motion restraints have a high impact on knee joint kinematics and wear behaviour of a fixed bearing posterior stabilised knee design.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23159092     DOI: 10.1016/j.jbiomech.2012.10.017

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  5 in total

1.  Experimental testing of total knee replacements with UHMW-PE inserts: impact of severe wear test conditions.

Authors:  Carmen Zietz; Joern Reinders; Jens Schwiesau; Alexander Paulus; Jan Philippe Kretzer; Thomas Grupp; Sandra Utzschneider; Rainer Bader
Journal:  J Mater Sci Mater Med       Date:  2015-02-26       Impact factor: 3.896

2.  Wear testing of moderate activities of daily living using in vivo measured knee joint loading.

Authors:  Jörn Reinders; Robert Sonntag; Leo Vot; Christian Gibney; Moritz Nowack; Jan Philippe Kretzer
Journal:  PLoS One       Date:  2015-03-26       Impact factor: 3.240

3.  Wear behavior of an unstable knee: stabilization via implant design?

Authors:  Jörn Reinders; Robert Sonntag; Jan Philippe Kretzer
Journal:  Biomed Res Int       Date:  2014-09-09       Impact factor: 3.411

4.  Posterior cruciate ligament balancing in total knee arthroplasty: a numerical study with a dynamic force controlled knee model.

Authors:  Arnd Steinbrück; Matthias Woiczinski; Patrick Weber; Peter Ernst Müller; Volkmar Jansson; Christian Schröder
Journal:  Biomed Eng Online       Date:  2014-07-02       Impact factor: 2.819

5.  The impact of variations in input directions according to ISO 14243 on wearing of knee prostheses.

Authors:  Xiao-Hong Wang; Wei Zhang; Da-Yong Song; Hui Li; Xiang Dong; Min Zhang; Feng Zhao; Zhong-Min Jin; Cheng-Kung Cheng
Journal:  PLoS One       Date:  2018-10-29       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.