Literature DB >> 23158328

A novel needle trap device with single wall carbon nanotubes sol-gel sorbent packed for sampling and analysis of volatile organohalogen compounds in air.

Mahmoud Heidari1, Abdolrahman Bahrami, Ali Reza Ghiasvand, Farshid Ghorbani Shahna, Ali Reza Soltanian.   

Abstract

This paper describes a new approach that combines needle trap devices (NTDs) with a newly synthesized silanated nano material as sorbent for sampling and analysis of HVOCs in air. The sol-gel technique was used for preparation of the single wall carbon nanotube (SWCNT)/silica composite as sorbent, packed inside a 21-gauge NTD. Application of this method as an exhaustive sampler device was investigated under different laboratory conditions in this study. Predetermined concentrations of each analyte were prepared in a home-made standard chamber, and the effects of experimental parameters, such as temperature, humidity, sampling air flow rate, breakthrough volume and storage time on NTD, and the sorbent performance were investigated. The proposed NTD was used in two different modes and two different injection methods, and an NTD with a side hole, a narrow neck glass liner and syringe pump assisted injection of carrier gas were applied. The NTD packed with SWCNTs/silica composite was compared to the NTD packed with PDMS and also SPME with CAR/PDMS. For four compounds, LOD was 0.001-0.01 ng mL(-1), LOQ was 0.007-0.03 ng mL(-1), and the relative standard division for repeatability of method was 2.5-6.7%. The results show that the incorporation of NTD and SWCNTs/silica composite is a reliable and effective approach for the sampling and analysis of HVOCs in air. Coupling this system to GC-MS make it more sensitive and powerful technique.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23158328     DOI: 10.1016/j.talanta.2012.09.032

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  5 in total

1.  Analysis of formaldehyde and acrolein in the aqueous samples using a novel needle trap device containing nanoporous silica aerogel sorbent.

Authors:  Abdullah Barkhordari; Mansour R Azari; Rezvan Zendehdel; Mahmoud Heidari
Journal:  Environ Monit Assess       Date:  2017-03-20       Impact factor: 2.513

2.  Preparation of Carbotrap/silica composite for needle trap field sampling of halogenated volatile organic compounds followed by gas chromatography/mass spectrometry determination.

Authors:  Ali Poormohammadi; Abdulrahman Bahrami; Alireza Ghiasvand; Farshid Ghorbani Shahna; Maryam Farhadian
Journal:  J Environ Health Sci Eng       Date:  2019-12-05

3.  Solid-phase microextraction fiber development for sampling and analysis of volatile organohalogen compounds in air.

Authors:  Seyed Ghavameddin Attari; Abdolrahman Bahrami; Farshid Ghorbani Shahna; Mahmoud Heidari
Journal:  J Environ Health Sci Eng       Date:  2014-09-17

4.  Discrimination of volatiles in herbal formula Baizhu Shaoyao San before and after processing using needle trap device with multivariate data analysis.

Authors:  Yangyang Xu; Hao Cai; Gang Cao; Yu Duan; Ke Pei; Jia Zhou; Li Xie; Jiayu Zhao; Jing Liu; Xiaoqi Wang; Lin Shen
Journal:  R Soc Open Sci       Date:  2018-06-20       Impact factor: 2.963

Review 5.  Nanosorbents as Materials for Extraction Processes of Environmental Contaminants and Others.

Authors:  María José Santoyo Treviño; Sergio Zarazúa; Justyna Płotka-Wasylka
Journal:  Molecules       Date:  2022-02-05       Impact factor: 4.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.