Literature DB >> 23153800

Virtual anthropology: a comparison between the performance of conventional X-ray and MDCT in investigating the trabecular structure of long bones.

Sébastien de Froidmont1, Silke Grabherr, Paul Vaucher, Mariangela De Cesare, Coraline Egger, Christina Papageorgopoulou, Viviane Roth, Grégoire Morand, Patrice Mangin, Tanya Uldin.   

Abstract

Recently, modern cross-sectional imaging techniques such as multi-detector computed tomography (MDCT) have pioneered post mortem investigations, especially in forensic medicine. Such approaches can also be used to investigate bones non-invasively for anthropological purposes. Long bones are often examined in forensic cases because they are frequently discovered and transferred to medico-legal departments for investigation. To estimate their age, the trabecular structure must be examined. This study aimed to compare the performance of MDCT with conventional X-rays to investigate the trabecular structure of long bones. Fifty-two dry bones (24 humeri and 28 femora) from anthropological collections were first examined by conventional X-ray, and then by MDCT. Trabecular structure was evaluated by seven observers (two experienced and five inexperienced in anthropology) who analyzed images obtained by radiological methods. Analyses contained the measurement of one quantitative parameter (caput diameter of humerus and femur) and staging the trabecular structure of each bone. Preciseness of each technique was indicated by describing areas of trabecular destruction and particularities of the bones, such as pathological changes. Concerning quantitative parameters, the measurements demonstrate comparable results for the MDCT and conventional X-ray techniques. In contrast, the overall inter-observer reliability of the staging was low with MDCT and conventional X-ray. Reliability increased significantly when only the results of the staging performed by the two experienced observers were compared, particularly regarding the MDCT analysis. Our results also indicate that MDCT appears to be better suited to a detailed examination of the trabecular structure. In our opinion, MDCT is an adequate tool with which to examine the trabecular structure of long bones. However, adequate methods should be developed or existing methods should be adapted to MDCT.
Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23153800     DOI: 10.1016/j.forsciint.2012.10.029

Source DB:  PubMed          Journal:  Forensic Sci Int        ISSN: 0379-0738            Impact factor:   2.395


  4 in total

Review 1.  Evaluating osteological ageing from digital data.

Authors:  Chiara Villa; Jo Buckberry; Niels Lynnerup
Journal:  J Anat       Date:  2016-09-13       Impact factor: 2.610

2.  Virtual anthropology: a preliminary test of macroscopic observation versus 3D surface scans and computed tomography (CT) scans.

Authors:  Claudine Abegg; Ilaria Balbo; Alejandro Dominguez; Silke Grabherr; Lorenzo Campana; Negahnaz Moghaddam
Journal:  Forensic Sci Res       Date:  2020-10-30

Review 3.  Virtual anthropology - a brief review of the literature and history of computed tomography.

Authors:  Tanya Uldin
Journal:  Forensic Sci Res       Date:  2017-09-14

4.  CT-scan vs. 3D surface scanning of a skull: first considerations regarding reproducibility issues.

Authors:  Stella Fahrni; Lorenzo Campana; Alejandro Dominguez; Tanya Uldin; Fabrice Dedouit; Olivier Delémont; Silke Grabherr
Journal:  Forensic Sci Res       Date:  2017-06-13
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.