Eye lens dosimetry in interventional cardiology: results of staff dose measurements and link to patient dose levels.

V Antic1, O Ciraj-Bjelac, M Rehani, S Aleksandric, D Arandjic, M Ostojic.   

Abstract

Workers involved in interventional cardiology procedures receive high eye lens dose if protection is not used. Currently, there is no suitable method for routine use for the measurement of eye dose. Since most angiography machines are equipped with suitable patient dosemeters, deriving factors linking staff eye doses to the patient doses can be helpful. In this study the patient kerma-area product, cumulative dose at an interventional reference point and eye dose in terms of Hp(3) of the cardiologists, nurses and radiographers for interventional cardiology procedures have been measured. Correlations between the patient dose and the staff eye dose were obtained. The mean eye dose was 121 µSv for the first operator, 33 µSv for the second operator/nurse and 12 µSv for radiographer. Normalised eye lens doses per unit kerma-area product were 0.94 µSv Gy⁻¹ cm⁻² for the first operator, 0.33 µSv Gy⁻¹ cm⁻² for the second operator/nurse and 0.16 µSv Gy⁻¹ cm⁻² for radiographers. Statistical analysis indicated that there is a weak but significant (p < 0.01) correlation between the eye dose and the kerma-area product for all three staff categories. These values are based on a local practice and may provide useful reference for other studies for validation and for wider utilisation in assessing the eye dose using patient dose values.

Entities:  

Mesh:

Year:  2012        PMID: 23152146     DOI: 10.1093/rpd/ncs236

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  5 in total

Review 1.  The current status of eye lens dose measurement in interventional cardiology personnel in Thailand.

Authors:  Anchali Krisanachinda; Suphot Srimahachota; Kosuke Matsubara
Journal:  Radiol Phys Technol       Date:  2017-05-27

Review 2.  Radiobiology in Cardiovascular Imaging.

Authors:  Pat Zanzonico; Lawrence Dauer; H William Strauss
Journal:  JACC Cardiovasc Imaging       Date:  2016-12

Review 3.  Eye protection in interventional procedures.

Authors:  Beth A Schueler; Kenneth A Fetterly
Journal:  Br J Radiol       Date:  2021-10-01       Impact factor: 3.629

Review 4.  Occupational radiation exposure to nursing staff during cardiovascular fluoroscopic procedures: A review of the literature.

Authors:  Kelly Wilson-Stewart; Madeleine Shanahan; Davide Fontanarosa; Rob Davidson
Journal:  J Appl Clin Med Phys       Date:  2018-10-08       Impact factor: 2.102

5.  Assessment of eye doses to staff involved in interventional cardiology procedures in Kuwait.

Authors:  Meshari Alnaaimi; Mousa Alduaij; Faisal Shenawy; Musab Algaily; Talal Mohammedzein; Mohamed Shaaban; Madan M Rehani
Journal:  Radiat Environ Biophys       Date:  2021-08-05       Impact factor: 1.925

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.