Literature DB >> 23151873

Use of the video telescope operating monitor (VITOM) as an alternative to the operating microscope in spine surgery.

Ali Shirzadi1, Debraj Mukherjee, Doniel G Drazin, Michelle Paff, Brian Perri, Adam N Mamelak, Khawar Siddique.   

Abstract

STUDY
DESIGN: Prospective cohort study.
OBJECTIVE: To evaluate the efficacy of video telescope operating monitor (VITOM) as an alternative to operative microscope (OM) in spinal surgery. SUMMARY OF BACKGROUND DATA: The surgical operating microscope can be expensive, cumbersome, and ergonomically disadvantageous. VITOM is a novel telescope-based exoscope system that can be used as an alternative or supplement to OM.
METHODS: Patients undergoing spinal surgery were enrolled in a prospective cohort study between December 2008 and March 2011. Age, sex, and operation-matched patients undergoing surgery using the standard OM served as the control group. During surgery, the VITOM system was used in place of the OM in 24 patients. Operative time, length of postoperative hospital stay, and intraoperative complications were assessed. RESULTS.: A total of 48 patients were studied in 2 equal cohorts of 24 patients each. Within each cohort, patients underwent single-level (n = 4) and 2-level (n = 7) posterior decompression as well as single-level (n = 11) and 2-level (n = 2) transforaminal lumbar interbody fusions via VITOM, with an equal number of controls using OM. There were no significant differences in age (P = 0.79) or sex (P = 0.77) between cohorts.There were no statistically significant differences in mean operative room time for single-level decompressions (P = 0.38), 2-level decompressions (P = 0.12), single-level transforaminal lumbar interbody fusions (P = 0.13), or 2-level transforaminal lumbar interbody fusions (P = 0.15). Postoperative hospital length of stay averaged 2.9 days for the VITOM group versus 2.8 days for the traditional OM group (P = 0.75). There were no intraoperative complications in either group. Subjectively, surgeons rated the image quality as very high and equal to the OM.
CONCLUSION: The VITOM system for spinal surgery provides outstanding image quality and an ease of manipulation rivaling the OM. There were no statistically significant differences in mean operative room time, intraoperative complications, or total hospital length of stay when using this novel system in several common spinal procedures relative to the OM.

Entities:  

Mesh:

Year:  2012        PMID: 23151873     DOI: 10.1097/BRS.0b013e3182709cef

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  14 in total

1.  Evaluation of a video telescopic operating microscope (VITOM) for pediatric surgery and urology: a preliminary report.

Authors:  Philip K Frykman; Barry P Duel; Alexandra Gangi; James A Williams; George Berci; Andrew L Freedman
Journal:  J Laparoendosc Adv Surg Tech A       Date:  2013-06-12       Impact factor: 1.878

Review 2.  Beyond magnification and illumination: preliminary clinical experience with the 4K 3D ORBEYE™ exoscope and a literature review.

Authors:  Michael Amoo; Jack Henry; Mohsen Javadpour
Journal:  Acta Neurochir (Wien)       Date:  2021-04-02       Impact factor: 2.216

3.  Clinical Application of a High Definition Three-Dimensional Exoscope in Anterior Lumbar Interbody Fusion: Technical Note.

Authors:  Manuela D'Ercole; Elena Serchi; Matteo Zanello; Tommaso Tufo; Carmelo Sturiale
Journal:  Int J Spine Surg       Date:  2020-12

4.  Robotic-assisted microsurgery for an elective microsurgical practice.

Authors:  Ahmet Gudeloglu; Jamin V Brahmbhatt; Sijo J Parekattil
Journal:  Semin Plast Surg       Date:  2014-02       Impact factor: 2.314

5.  Spine surgeon's kinematics during discectomy, part II: operating table height and visualization methods, including microscope.

Authors:  Jeong Yoon Park; Kyung Hyun Kim; Sung Uk Kuh; Dong Kyu Chin; Keun Su Kim; Yong Eun Cho
Journal:  Eur Spine J       Date:  2013-12-24       Impact factor: 3.134

6.  Optimal invasive key-hole neurosurgery with a miniaturized 3D chip on the tip: Microendoscopic device.

Authors:  Patra Charalampaki; Alhadi Igressa; Mehran Mahvash; Ioannis Pechlivanis; Bernhard Schick
Journal:  Asian J Neurosurg       Date:  2013-07

7.  Perforation and bacterial contamination of microscope covers in lumbar spinal decompressive surgery.

Authors:  Georg Osterhoff; José Spirig; Jürgen Klasen; Stefan P Kuster; Annelies S Zinkernagel; Hugo Sax; Kan Min
Journal:  Med Princ Pract       Date:  2014-06-04       Impact factor: 1.927

Review 8.  From Exoscope into the Next Generation.

Authors:  Kenichi Nishiyama
Journal:  J Korean Neurosurg Soc       Date:  2017-05-01

9.  Learning neuroendoscopy with an exoscope system (video telescopic operating monitor): Early clinical results.

Authors:  Vijay Parihar; Y R Yadav; Yatin Kher; Shailendra Ratre; Ashish Sethi; Dhananjaya Sharma
Journal:  Asian J Neurosurg       Date:  2016 Oct-Dec

10.  3D digital image microscope system-assisted vasovasostomy and vasoepididymostomy in rats.

Authors:  Peng Li; Na-Chuan Liu; Er-Lei Zhi; Chen-Cheng Yao; Zhi-Liang Zhao; Zhi-Yong Yu; Qi-Meng Li; Yu-Hua Huang; Jie-Chang Ju; Wen-Bin Huang; Husanjan Rozi; Zhi-Yong Ji; San-Wei Guo; Ru-Hui Tian; Zheng Li
Journal:  Asian J Androl       Date:  2021 Jul-Aug       Impact factor: 3.285

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.