Dynamic contrast-enhanced MR imaging of carotid atherosclerotic plaque: model selection, reproducibility, and validation.

Michaela E Gaens1, Walter H Backes, Stefan Rozel, Matthijs Lipperts, Stefan N Sanders, Karolien Jaspers, Jacques P M Cleutjens, Judith C Sluimer, Sylvia Heeneman, Mat J A P Daemen, Rob J T J Welten, Jan-Willem H Daemen, Joachim E Wildberger, Robert M Kwee, M Eline Kooi.   

Abstract

PURPOSE: To compare four known pharmacokinetic models for their ability to describe dynamic contrast material-enhanced magnetic resonance (MR) imaging of carotid atherosclerotic plaques, to determine reproducibility, and to validate the results with histologic findings.
MATERIALS AND METHODS: The study was approved by the institutional medical ethics committee. Written informed consent was obtained from all patients. Forty-five patients with 30%-99% carotid stenosis underwent dynamic contrast-enhanced MR imaging. Plaque enhancement was measured at 16 time points at approximately 25-second image intervals by using a gadolinium-based contrast material. Pharmacokinetic parameters (volume transfer constant, K(trans); extracellular extravascular volume fraction, v(e); and blood plasma fraction, v(p)) were determined by fitting a two-compartment model to plaque and blood gadolinium concentration curves. The relative fit errors and parameter uncertainties were determined to find the most suitable model. Sixteen patients underwent imaging twice to determine reproducibility. Carotid endarterectomy specimens from 16 patients who were scheduled for surgery were collected for histologic validation. Parameter uncertainties were compared with the Wilcoxon signed rank test. Reproducibility was assessed by using the coefficient of variation. Correlation with histologic findings was evaluated with the Pearson correlation coefficient.
RESULTS: The mean relative fit uncertainty (±standard error) for K(trans) was 10% ± 1 with the Patlak model, which was significantly lower than that with the Tofts (20% ± 1), extended Tofts (33% ± 3), and extended graphical (29% ± 3) models (P < .001). The relative uncertainty for v(p) was 20% ± 2 with the Patlak model and was significantly higher with the extended Tofts (46% ± 9) and extended graphical (35% ± 5) models (P < .001). The reproducibility (coefficient of variation) for the Patlak model was 16% for K(trans) and 26% for v(p). Significant positive correlations were found between K(trans) and the endothelial microvessel content determined on histologic slices (Pearson ρ = 0.72, P = .005).
CONCLUSION: The Patlak model is most suited for describing carotid plaque enhancement. Correlation with histologic findings validated K(trans) as an indicator of plaque microvasculature, and the reproducibility of K(trans) was good. RSNA, 2012

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23151823     DOI: 10.1148/radiol.12120499

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  36 in total

1.  New developments in clinical ischemic stroke prevention and treatment and their imaging implications.

Authors:  Jeremy J Heit; Max Wintermark
Journal:  J Cereb Blood Flow Metab       Date:  2017-02-14       Impact factor: 6.200

2.  Registration of dynamic contrast-enhanced MRI of the common carotid artery using a fixed-frame template-based squared-difference method.

Authors:  Sarayu Ramachandran; Claudia Calcagno; Venkatesh Mani; Philip M Robson; Zahi A Fayad
Journal:  J Magn Reson Imaging       Date:  2013-10-07       Impact factor: 4.813

3.  Atherosclerotic plaque inflammation quantification using dynamic contrast-enhanced (DCE) MRI.

Authors:  Huijun Chen; Tingting Wu; William S Kerwin; Chun Yuan
Journal:  Quant Imaging Med Surg       Date:  2013-12

Review 4.  State-of-the-art MRI techniques in neuroradiology: principles, pitfalls, and clinical applications.

Authors:  Magalie Viallon; Victor Cuvinciuc; Benedicte Delattre; Laura Merlini; Isabelle Barnaure-Nachbar; Seema Toso-Patel; Minerva Becker; Karl-Olof Lovblad; Sven Haller
Journal:  Neuroradiology       Date:  2015-04-10       Impact factor: 2.804

5.  Large coverage black-bright blood interleaved imaging sequence (LaBBI) for 3D dynamic contrast-enhanced MRI of vessel wall.

Authors:  Haikun Qi; Feng Huang; Zechen Zhou; Peter Koken; Niranjan Balu; Bida Zhang; Chun Yuan; Huijun Chen
Journal:  Magn Reson Med       Date:  2017-06-19       Impact factor: 4.668

6.  Ischemic Stroke Patients Demonstrate Increased Carotid Plaque Microvasculature Compared to (Ocular) Transient Ischemic Attack Patients.

Authors:  Raf H M van Hoof; Floris H B M Schreuder; Patty Nelemans; Martine T B Truijman; Narender P van Orshoven; Tobien H Schreuder; Werner H Mess; Sylvia Heeneman; Robert J van Oostenbrugge; Joachim E Wildberger; M Eline Kooi
Journal:  Cerebrovasc Dis       Date:  2017-09-26       Impact factor: 2.762

7.  64Cu-ATSM Positron Emission Tomography/Magnetic Resonance Imaging of Hypoxia in Human Atherosclerosis.

Authors:  Xingyu Nie; Andrew Elvington; Richard Laforest; Jie Zheng; Thomas F Voller; Mohamed A Zayed; Dana R Abendschein; Nilantha Bandara; Jinbin Xu; Ran Li; Gwendalyn J Randolph; Robert J Gropler; Suzanne E Lapi; Pamela K Woodard
Journal:  Circ Cardiovasc Imaging       Date:  2020-01-08       Impact factor: 7.792

Review 8.  Susceptibility-weighted imaging: current status and future directions.

Authors:  Saifeng Liu; Sagar Buch; Yongsheng Chen; Hyun-Seok Choi; Yongming Dai; Charbel Habib; Jiani Hu; Joon-Yong Jung; Yu Luo; David Utriainen; Meiyun Wang; Dongmei Wu; Shuang Xia; E Mark Haacke
Journal:  NMR Biomed       Date:  2016-05-18       Impact factor: 4.044

9.  Adventitial perfusion and intraplaque hemorrhage: a dynamic contrast-enhanced MRI study in the carotid artery.

Authors:  Jie Sun; Yan Song; Huijun Chen; William S Kerwin; Daniel S Hippe; Li Dong; Min Chen; Cheng Zhou; Thomas S Hatsukami; Chun Yuan
Journal:  Stroke       Date:  2013-03-07       Impact factor: 7.914

Review 10.  Imaging and nanomedicine in inflammatory atherosclerosis.

Authors:  Willem J M Mulder; Farouc A Jaffer; Zahi A Fayad; Matthias Nahrendorf
Journal:  Sci Transl Med       Date:  2014-06-04       Impact factor: 17.956

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.