Literature DB >> 23150161

Quadriceps tendon rupture: a biomechanical comparison of transosseous equivalent double-row suture anchor versus transosseous tunnel repair.

Nathan D Hart1, Matthew K Wallace, J Field Scovell, Ryan J Krupp, Chad Cook, Douglas J Wyland.   

Abstract

Quadriceps rupture off the patella is traditionally repaired by a transosseous tunnel technique, although a single-row suture anchor repair has recently been described. This study biomechanically tested a new transosseous equivalent (TE) double-row suture anchor technique compared with the transosseous repair for quadriceps repair. After simulated quadriceps-patella avulsion in 10 matched cadaveric knees, repairs were completed by either a three tunnel transosseous (TT = 5) or a TE suture anchor (TE = 5) technique. Double-row repairs were done using two 5.5 Bio-Corkscrew FT (fully threaded) (Arthrex, Inc., Naples, FL, USA) and two 3.5 Bio-PushLock anchors (Arthrex, Inc., Naples, FL, USA) with all 10 repairs done with #2 FiberWire suture (Arthrex, Inc., Naples, FL). Cyclic testing from 50 to 250 N for 250 cycles and pull to failure load (1 mm/s) were undertaken. Gap formation and ultimate tensile load (N) were recorded and stiffness data (N/mm) were calculated. Statistical analysis was performed using a Mann-Whitney U test and survival characteristics examined with Kaplan-Meier test. No significant difference was found between the TE and TT groups in stiffness (TE = 134 +/- 15 N/mm, TT = 132 +/- 26 N/mm, p = 0.28). The TE group had significantly less ultimate tensile load (N) compared with the TT group (TE = 447 +/- 86 N, TT = 591 +/- 84 N, p = 0.04), with all failures occurring at the suture eyelets. Although both quadriceps repairs were sufficiently strong, the transosseous repairs were stronger than the TE suture anchor repairs. The repair stiffness and gap formation were similar between the groups.

Entities:  

Mesh:

Year:  2012        PMID: 23150161     DOI: 10.1055/s-0031-1299656

Source DB:  PubMed          Journal:  J Knee Surg        ISSN: 1538-8506            Impact factor:   2.757


  12 in total

1.  The elastic capacity of a tendon-repair construct influences the force necessary to induce gapping.

Authors:  Atesch Ateschrang; Christoph Salewski; Marc-Daniel Ahrend; Anna Janine Schreiner; Michael T Hirschmann; Ulrich Stöckle; Sufian S Ahmad
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-05-14       Impact factor: 4.342

2.  Quadriceps tendon tear rupture in healthy patients treated with patellar drilling holes: clinical and ultrasonographic analysis after 36 months of follow-up.

Authors:  Michele Arcangelo Verdano; Matteo Zanelli; Davide Aliani; Tiziana Corsini; Andrea Pellegrini; Francesco Ceccarelli
Journal:  Muscles Ligaments Tendons J       Date:  2014-07-14

Review 3.  Extensor mechanism ruptures.

Authors:  Reha N Tandogan; Esref Terzi; Enrique Gomez-Barrena; Bruno Violante; Asim Kayaalp
Journal:  EFORT Open Rev       Date:  2022-05-31

4.  TREATMENT OF QUADRICEPS TENDON RUPTURE IN HEMODIALYSIS PATIENTS: A 2020 UPDATE.

Authors:  Luis Marcelo de Azevedo Malta; Alair Augusto Sarmet Moreira Damas Dos Santos; Marcio Carpi Malta; Leonardo Martins Machado; Jocemir Ronaldo Lugon
Journal:  Acta Ortop Bras       Date:  2022-07-06       Impact factor: 0.683

5.  Anchor suture fixation of distal pole fractures of patella: twenty seven cases and comparison to partial patellectomy.

Authors:  Assaf Kadar; Haggai Sherman; Michael Drexler; Eldad Katz; Ely L Steinberg
Journal:  Int Orthop       Date:  2015-04-26       Impact factor: 3.075

6.  Transosseous-Equivalent Repair for Distal Patellar Tendon Avulsion.

Authors:  David K Galos; Sanjit R Konda; Daniel J Kaplan; William E Ryan; Michael J Alaia
Journal:  Arthrosc Tech       Date:  2016-04-18

7.  Suture anchor repair yields better biomechanical properties than transosseous sutures in ruptured quadriceps tendons.

Authors:  M Petri; A Dratzidis; S Brand; T Calliess; C Hurschler; C Krettek; M Jagodzinski; M Ettinger
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-01-29       Impact factor: 4.342

8.  Arthroscopic quadriceps tendon repair: two case reports.

Authors:  Hidetomo Saito; Yoichi Shimada; Toshiaki Yamamura; Shin Yamada; Takahiro Sato; Koji Nozaka; Hiroaki Kijima; Kimio Saito
Journal:  Case Rep Orthop       Date:  2015-02-28

9.  Open Repair of Quadriceps Tendon With Suture Anchors and Semitendinosus Tendon Allograft Augmentation.

Authors:  Jorge Chahla; Nicholas N DePhillipo; Mark E Cinque; Nicholas I Kennedy; George F Lebus; Filippo Familiari; Gilbert Moatshe; Robert F LaPrade
Journal:  Arthrosc Tech       Date:  2017-11-06

10.  Adjustable Cortical Fixation Device for Quadriceps Tendon Repair: A Cadaveric Biomechanical Study.

Authors:  Heath P Gould; William R Rate; Pooyan Abbasi; Katherine L Mistretta; Jason W Hammond
Journal:  Orthop J Sports Med       Date:  2021-01-28
View more