Literature DB >> 23147823

Study of the efficiency for ion transfer through bent capillaries.

Tsung-Chi Chen1, Wei Xu, Sandilya Garimella, Zheng Ouyang.   

Abstract

Discontinuous atmospheric pressure interfaces (DAPIs) with bent capillaries represent a highly simplified and flexible means for introducing ions into a vacuum manifold for mass analysis or gas phase ion reactions. In this work, a series of capillaries of different radians and curvatures were used with DAPI for studying the impact of the capillary bending on the ion transfer. The variation of transfer efficiency was systematically characterized for dry and solvated ions. The efficiency loss for dry ions was less than one order of magnitude, even with a three-turn bent capillary. The transfer of solvated ions generated by electrospray was found to be minimally impacted by the bending of the transfer capillary. For multiply protonated ions, the transfer efficiency for ions at lower charge states could be relatively well retained, presumably due to the lower reactivity associated with proton transfer reaction and the compensation in intensity by conversion of ions at higher charge states.
Copyright © 2012 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23147823     DOI: 10.1002/jms.3117

Source DB:  PubMed          Journal:  J Mass Spectrom        ISSN: 1076-5174            Impact factor:   1.982


  6 in total

1.  Simulation of rarefied gas flows in atmospheric pressure interfaces for mass spectrometry systems.

Authors:  Sandilya Garimella; Xiaoyu Zhou; Zheng Ouyang
Journal:  J Am Soc Mass Spectrom       Date:  2013-09-17       Impact factor: 3.109

2.  Design of portable mass spectrometers with handheld probes: aspects of the sampling and miniature pumping systems.

Authors:  Chien-Hsun Chen; Tsung-Chi Chen; Xiaoyu Zhou; Robert Kline-Schoder; Paul Sorensen; R Graham Cooks; Zheng Ouyang
Journal:  J Am Soc Mass Spectrom       Date:  2014-11-18       Impact factor: 3.109

3.  Gas Flow in the Capillary of the Atmosphere-to-Vacuum Interface of Mass Spectrometers.

Authors:  Michael Skoblin; Alexey Chudinov; Ilia Soulimenkov; Vladimir Brusov; Viacheslav Kozlovskiy
Journal:  J Am Soc Mass Spectrom       Date:  2017-07-18       Impact factor: 3.109

4.  Characterization of a DAPI-RIT-DAPI system for gas-phase ion/molecule and ion/ion reactions.

Authors:  Ziqing Lin; Lei Tan; Sandilya Garimella; Linfan Li; Tsung-Chi Chen; Wei Xu; Yu Xia; Zheng Ouyang
Journal:  J Am Soc Mass Spectrom       Date:  2013-10-23       Impact factor: 3.109

5.  Real-time sample analysis using a sampling probe and miniature mass spectrometer.

Authors:  Chien-Hsun Chen; Ziqing Lin; Ran Tian; Riyi Shi; R Graham Cooks; Zheng Ouyang
Journal:  Anal Chem       Date:  2015-08-10       Impact factor: 6.986

6.  Ion sponge: a 3-dimentional array of quadrupole ion traps for trapping and mass-selectively processing ions in gas phase.

Authors:  Wei Xu; Linfan Li; Xiaoyu Zhou; Zheng Ouyang
Journal:  Anal Chem       Date:  2014-04-28       Impact factor: 6.986

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.