Literature DB >> 23146934

Influence of the precutting and overseas transportation of corneal grafts for Descemet stripping automated endothelial keratoplasty on donor endothelial cell loss.

Kyoko Yamazoe1, Katsuya Yamazoe, Naoshi Shinozaki, Jun Shimazaki.   

Abstract

PURPOSE: The authors evaluated the changes in donor endothelial cell density (ECD) caused by the precutting and long-distance transportation of corneal grafts for Descemet stripping automated endothelial keratoplasty (DSAEK) from overseas eye banks.
METHODS: A total of 124 consecutive precut donor tissues for DSAEK were obtained from overseas eye banks. The ECD was examined before precutting, after precutting, and after overseas transportation. Changes in ECD secondary to the precutting procedure and after long-distance transportation were evaluated.
RESULTS: The average ECD before and after precutting was 2637 ± 336 and 2578 ± 305, respectively (P = 0.0063). The ECD after overseas transportation was 2468 ± 272, which is a significant decrease compared with the ECD after the precutting procedure (P < 0.001). The average rate of ECD loss was 1.75% for precutting and 3.79% for overseas transportation, with a total ECD loss of 5.68%. The ECD before surgery was >2000 cells per square millimeter in all cases, and all grafts were available for DSAEK.
CONCLUSIONS: Imported precut donor corneas form overseas eye banks are a valuable source of donor corneas for DSAEK. The cell loss associated with precutting and the overseas transportation of corneal grafts on donor endothelial cell loss is acceptable.

Entities:  

Mesh:

Year:  2013        PMID: 23146934     DOI: 10.1097/ICO.0b013e3182732d88

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  5 in total

Review 1.  Eye-bank preparation of endothelial tissue.

Authors:  Grace E Boynton; Maria A Woodward
Journal:  Curr Opin Ophthalmol       Date:  2014-07       Impact factor: 3.761

2.  Outcomes of descemet stripping automated endothelial keratoplasty using imported donor corneas.

Authors:  Kaevalin Lekhanont; Kavin Vanikieti; Nutthida Nimvorapun; Varintorn Chuckpaiwong
Journal:  BMC Ophthalmol       Date:  2017-04-05       Impact factor: 2.209

3.  Clinical outcomes after Descemet's stripping endothelial keratoplasty using donor corneas from children younger than 3 years.

Authors:  Rong-Mei Peng; Yu-Xin Guo; Yuan Qiu; Jing Hong; Ge-Ge Xiao; Hong-Qiang Qu
Journal:  Clin Exp Ophthalmol       Date:  2018-03-30       Impact factor: 4.207

4.  Clinical Outcomes of Penetrating Keratoplasty and Descemet Stripping Automated Endothelial Keratoplasty in Asian Population with American Corneas.

Authors:  Fang-Chi Hsiao; Po-Yuan Chen; Yaa-Jyuhn James Meir; Hsin-Yuan Tan; Ching-Hsi Hsiao; Hsin-Chiung Lin; David Hui-Kang Ma; Lung-Kun Yeh; Wei-Chi Wu; Hung-Chi Chen
Journal:  Int J Environ Res Public Health       Date:  2019-11-17       Impact factor: 3.390

5.  Cost Minimization Analysis of Precut Cornea Grafts in Descemet Stripping Automated Endothelial Keratoplasty.

Authors:  Kai-Ling Yong; Hai V Nguyen; Howard Y Cajucom-Uy; Valencia Foo; Donald Tan; Eric A Finkelstein; Jodhbir S Mehta
Journal:  Medicine (Baltimore)       Date:  2016-02       Impact factor: 1.889

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.