Literature DB >> 23146916

Effects of vigorous mixing of blood vacuum tubes on laboratory test results.

Gabriel Lima-Oliveira1, Giuseppe Lippi, Gian Luca Salvagno, Martina Montagnana, Matteo Gelati, Waldemar Volanski, Katia Cristina Boritiza, Geraldo Picheth, Gian Cesare Guidi.   

Abstract

OBJECTIVE: To evaluate the effect of tubes mixing (gentle vs. vigorous) on diagnostic blood specimens collected in vacuum tube systems by venipuncture. DESIGN AND METHODS: Blood was collected for routine coagulation, immunochemistry and hematological testing from one hundred volunteers into six vacuum tubes: two 3.6 mL vacuum tubes containing 0.4 mL of buffered sodium citrate (9NC) 0.109 mol/L: 3.2 W/V%; two 3.5 mL vacuum tubes with clot activator and gel separator; and two 3.0 mL vacuum tubes containing 5.9 mg K(2)EDTA (Terumo Europe, Belgium). Immediately after the venipuncture all vacuum tubes (each of one additive type) were processed through two different procedures: i) Standard: blood specimens in K(2)EDTA- or sodium citrate-vacuum tubes were gently inverted five times whereas the specimens in tubes with clot activator and gel separator were gently inverted ten times, as recommended by the manufacturer; ii) Vigorous mix: all blood specimens were shaken up vigorously during 3-5s independently of the additive type inside the tubes. The significance of the differences between samples was assessed by Student's t-test or Wilcoxon ranked-pairs test after checking for normality. The level of statistical significance was set at P<0.05.
RESULTS: No significant difference (P<0.05) was detected between the procedures for all tested parameters. Surprisingly only a visual alteration (presence of foam on the top) was shown by all the tubes mixed vigorously before centrifugation (Fig. 1 A, B and C). Moreover the serum tubes from vigorous mixing procedure shows a "blood ring" on the tube top after stopper removal (Fig. 1 D).
CONCLUSION: Our results drop out a paradigm suggesting that the incorrect primary blood tubes mixing promotes laboratory variability. We suggest that similar evaluation should be done using other brands of vacuum tubes by each laboratory manager.
Copyright © 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23146916     DOI: 10.1016/j.clinbiochem.2012.10.033

Source DB:  PubMed          Journal:  Clin Biochem        ISSN: 0009-9120            Impact factor:   3.281


  12 in total

1.  Quality impact on diagnostic blood specimen collection using a new device to relieve venipuncture pain.

Authors:  Gabriel Lima-Oliveira; Giuseppe Lippi; Gian Luca Salvagno; Martina Montagnana; Geraldo Picheth; Gian Cesare Guidi
Journal:  Indian J Clin Biochem       Date:  2013-04-03

2.  The impact of fist clenching and its maintenance during venipuncture on routine hematology testing.

Authors:  Gabriel Lima-Oliveira; Gian Cesare Guidi; Gian Luca Salvagno; Giuseppe Lippi
Journal:  J Clin Lab Anal       Date:  2016-11-29       Impact factor: 2.352

3.  Guidance on the critical shortage of sodium citrate coagulation tubes for hemostasis testing.

Authors:  Robert C Gosselin; Annette Bowyer; Emmanuel J Favaloro; Jill M Johnsen; Giuseppe Lippi; Richard A Marlar; Keith Neeves; Marian A Rollins-Raval
Journal:  J Thromb Haemost       Date:  2021-09-02       Impact factor: 16.036

4.  Personnel's Experiences of Phlebotomy Practices after Participating in an Educational Intervention Programme.

Authors:  Karin Bölenius; Christine Brulin; Ulla H Graneheim
Journal:  Nurs Res Pract       Date:  2014-10-30

5.  Could light meal jeopardize laboratory coagulation tests?

Authors:  Gabriel Lima-Oliveira; Gian Luca Salvagno; Giuseppe Lippi; Elisa Danese; Matteo Gelati; Martina Montagnana; Geraldo Picheth; Gian Cesare Guidi
Journal:  Biochem Med (Zagreb)       Date:  2014-10-15       Impact factor: 2.313

Review 6.  Laboratory Diagnostics and Quality of Blood Collection.

Authors:  Gabriel Lima-Oliveira; Giuseppe Lippi; Gian Luca Salvagno; Geraldo Picheth; Gian Cesare Guidi
Journal:  J Med Biochem       Date:  2015-07-14       Impact factor: 3.402

7.  Preanalytical Nonconformity Management Regarding Primary Tube Mixing in Brazil.

Authors:  Gabriel Lima-Oliveira; Gian Cesare Guidi; Andre Valpassos Pacifici Guimaraes; Jose Abol Correa; Giuseppe Lippi
Journal:  J Med Biochem       Date:  2017-01-25       Impact factor: 3.402

Review 8.  Preanalytical investigations of phlebotomy: methodological aspects, pitfalls and recommendations.

Authors:  Cristiano Ialongo; Sergio Bernardini
Journal:  Biochem Med (Zagreb)       Date:  2017-02-15       Impact factor: 2.313

9.  The effective reduction of tourniquet application time after minor modification of the CLSI H03-A6 blood collection procedure.

Authors:  Gabriel Lima-Oliveira; Giuseppe Lippi; Gian Luca Salvagno; Martina Montagnana; Geraldo Picheth; Gian Cesare Guidi
Journal:  Biochem Med (Zagreb)       Date:  2013       Impact factor: 2.313

10.  Impact of a large-scale educational intervention program on venous blood specimen collection practices.

Authors:  Karin Bölenius; Marie Lindkvist; Christine Brulin; Kjell Grankvist; Karin Nilsson; Johan Söderberg
Journal:  BMC Health Serv Res       Date:  2013-11-05       Impact factor: 2.655

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.