Literature DB >> 23142463

Preparation and characterization of monoclonal antibody specific for copper-chelate complex.

Fengquan Liu1, Yang Lou, Xiuying Shi, Huiming Wang, Xiaoxia Zhu.   

Abstract

Monoclonal antibody (MAb) against chelated Cu(2+) was developed. The conjugate employed as immunogens in BALB/c mice to raise antibodies was synthesized using Cu(2+) coupling to keyhole limpet hemocyanin (KLH) via a bifunctional chelator (2-(4-isothiocyanatobenzyl)-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid, p-SCN-Bn-DOTA). One of the hybridomas secreting antibody that bound tightly to Cu(2+)-ethylenediamine tetraacetic acid (EDTA) complex but not to metal-free EDTA was isolated from the fusion between murine splenocytes and SP2/0 myeloma cells. The performance of a competitive enzyme-linked immunosorbent assay (ELISA) was assessed for its sensitivity to changes in pH and ionic strength. The cross-reactivities (CR) with other metals were below 1%, except for Hg(2+) with a CR of 7.19 %. The IC(50) value achieved for copper was 0.89 μg/mL, showing a detection range of 0.25-8.13 μg/mL and the lowest detection limit of 0.032 μg/mL. The concentration of Cu(2+) in environmental water and serum samples obtained by ELISA correlated well with Atomic Absorption Spectrometry (AAS), and the mean recovery was 93.7%. These results indicated that ELISA could be a convenient analytical tool for monitoring copper in drinking water and human serum.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23142463     DOI: 10.1016/j.jim.2012.11.001

Source DB:  PubMed          Journal:  J Immunol Methods        ISSN: 0022-1759            Impact factor:   2.303


  3 in total

1.  Analyte-triggered cyclic autocatalytic oxidation amplification combined with an upconversion nanoparticle probe for fluorometric detection of copper(II).

Authors:  Hongyu Chen; Kaili He; Huan Li; Youyu Zhang; Shouzhuo Yao
Journal:  Mikrochim Acta       Date:  2018-10-01       Impact factor: 5.833

2.  Indirect Competitive ELISA for the Determination of Total Chromium Content in Food, Feed and Environmental Samples.

Authors:  Xiaofei Wang; Yanan Wang; Shuyun Wang; Jie Hou; Linlin Cai; Guoying Fan
Journal:  Molecules       Date:  2022-02-27       Impact factor: 4.411

3.  Detection of cystatin C biomarker for clinical measurement of renal disease by developed ELISA diagnostic kits.

Authors:  Renren Jiang; Chao Xu; Xiaoli Zhou; Tianhao Wang; Gang Yao
Journal:  J Transl Med       Date:  2014-09-12       Impact factor: 5.531

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.