Literature DB >> 23141325

Virtual electrochemical nitric oxide analyzer using copper, zinc superoxide dismutase immobilized on carbon nanotubes in polypyrrole matrix.

Thangamuthu Madasamy1, Manickam Pandiaraj, Murugesan Balamurugan, Santosh Karnewar, Alby Robson Benjamin, Krishna Arun Venkatesh, Kanagavel Vairamani, Srigiridhar Kotamraju, Chandran Karunakaran.   

Abstract

In this work, we have designed and developed a novel and cost effective virtual electrochemical analyzer for the measurement of NO in exhaled breath and from hydrogen peroxide stimulated endothelial cells using home-made potentiostat. Here, data acquisition system (NI MyDAQ) was used to acquire the data from the electrochemical oxidation of NO mediated by copper, zinc superoxide dismutase (Cu,ZnSOD). The electrochemical control programs (graphical user-interface software) were developed using LabVIEW 10.0 to sweep the potential, acquire the current response and process the acquired current signal. The Cu,ZnSOD (SOD1) immobilized on the carbon nanotubes in polypyrrole modified platinum electrode was used as the NO biosensor. The electrochemical behavior of the SOD1 modified electrode exhibited the characteristic quasi-reversible redox peak at the potential, +0.06 V vs. Ag/AgCl. The biological interferences were eliminated by nafion coated SOD1 electrode and then NO was measured selectively. Further, this biosensor showed a wide linear range of response over the concentration of NO from 0.1 μM to 1 mM with a detection limit of 0.1 μM and high sensitivity of 1.1 μA μM(-1). The electroanalytical results obtained here using the developed virtual electrochemical instrument were also compared with the standard cyclic voltammetry instrument and found in agreement with each other.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23141325     DOI: 10.1016/j.talanta.2012.08.033

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

Review 1.  Technologies for Clinical Diagnosis Using Expired Human Breath Analysis.

Authors:  Thalakkotur Lazar Mathew; Prabhahari Pownraj; Sukhananazerin Abdulla; Biji Pullithadathil
Journal:  Diagnostics (Basel)       Date:  2015-02-02

Review 2.  Fractional exhaled nitric oxide-measuring devices: technology update.

Authors:  Mauro Maniscalco; Carolina Vitale; Alessandro Vatrella; Antonio Molino; Andrea Bianco; Gennaro Mazzarella
Journal:  Med Devices (Auckl)       Date:  2016-06-23

3.  Label-Free Electrochemical Immunoassay for C-Reactive Protein.

Authors:  Madasamy Thangamuthu; Christian Santschi; Olivier J F Martin
Journal:  Biosensors (Basel)       Date:  2018-03-30
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.