Literature DB >> 23141162

[Distribution and normal reference range of fetal nuchal translucency thickness in Kunming pregnant women in the first trimester].

Qian Sun1, Jing Xu, Shun-qin Hu, Min Chen, Run-mei Ma, Tze Kin Lau, Lan Zhang, Xue Xiao, Yuan Qian, Zhi Guo.   

Abstract

OBJECTIVE: To establish the normal reference range of fetal nuchal translucency (NT) thickness in Kunming Chinese pregnant women in the first trimester.
METHODS: The study samples comprised of 1790 Kunming pregnant women who attended antenatal visit in the first trimester in the First Affiliated Hospital of Kunming Medical University. The general information including maternal date of birth, past pregnant history and other related conditions were recorded. The crown rump length (CRL) and NT thickness at 11 - 13(+6) gestational weeks were measured according to guidelines from Fetal Medicine Foundation (FMF).
RESULTS: The total 1790 of normal fetuses was recruited for final analysis. The mean and median values of CRL were (59.6 ± 9.2) mm and 58.3 mm, respectively. The mean and median values of NT thickness were (1.7 ± 0.5) mm and 1.7 mm, respectively. While the CRL were at between 45.0 - 54.9 mm, 55.0 - 64.9 mm, 65.0 - 74.9 mm and 75.0 - 84.0 mm, the corresponding values of NT thickness were 1.0 mm, 1.3 mm, 1.5 mm, 1.5 mm at the 5(th) percentile and 2.0 mm, 2.5 mm, 2.7 mm, 2.9 mm at the 95(th) percentile, respectively, and the corresponding medial values of NT thickness were 1.4 mm, 1.7 mm, 2.0 mm, 2.0 mm, respectively. The NT thickness had no relationship with maternal age (P > 0.05). The mean value of NT thickness was (1.8 ± 1.1) mm in male fetuses. The mean value of NT thickness was (1.7 ± 0.6) mm in female fetuses. The NT thickness in male fetuses was significantly thicker than that of females (P = 0.001).
CONCLUSION: The present study established a reference range of normal fetal NT thickness corresponding with CRL in early pregnancy with reliable FMF quality control.

Entities:  

Mesh:

Year:  2012        PMID: 23141162

Source DB:  PubMed          Journal:  Zhonghua Fu Chan Ke Za Zhi        ISSN: 0529-567X


  3 in total

1.  Normal reference range of fetal nuchal translucency thickness in pregnant women in the first trimester, one center study.

Authors:  Marzeie Sharifzadeh; Atoosa Adibi; Kimia Kazemi; Silva Hovsepian
Journal:  J Res Med Sci       Date:  2015-10       Impact factor: 1.852

2.  Intracranial translucency as a sonographic marker for detecting open spina bifida at 11-13+6 weeks scan: Our experience.

Authors:  Madhavi L Teegala; Dhamangaonkar G Vinayak
Journal:  Indian J Radiol Imaging       Date:  2017 Oct-Dec

3.  Do the Levels of Maternal Plasma Trace Elements Affect Fetal Nuchal Translucency Thickness?

Authors:  Kai-Wei Liao; Ming-Song Tsai; Chia-Huang Chang; Ling-Chu Chien; I-Fang Mao; Yen-An Tsai; Mei-Lien Chen
Journal:  PLoS One       Date:  2015-09-14       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.