| Literature DB >> 23139860 |
Madhuri Thakur1, Steven L Sinsabaugh, Mark J Isaacson, Michael S Wong, Sibani Lisa Biswal.
Abstract
One of the most exciting areas inEntities:
Year: 2012 PMID: 23139860 PMCID: PMC3493010 DOI: 10.1038/srep00795
Source DB: PubMed Journal: Sci Rep ISSN: 2045-2322 Impact factor: 4.379
Figure 1(a) Description of process to generate a MPSP/PPAN composite material from a free standing macroporous silicon film.(b) Corresponding scanning electron microscope (SEM) images for freestanding macroporous silicon film, a sonicated film forming macroporous silicon micro-particulates (MPSPs), MPSPs mixed with PAN, and MPSP/PPAN after pyrolysis; (c) SEM image and volume comparison between a 50mg powder sample of macroporous silicon micro-particulates (MPSP) and with crushed silicon particulates.
Figure 2(a) Comparison of the discharge capacity and coulombic efficiency of composite of MPSP versus crushed silicon particulates mixed with PPAN versus cycle number; (b) Comparison of the discharge capacity and coulombic efficiency of MPSPs/PPAN anodes at various ratios versus cycle number.
Various mass ratios of MPSP: PAN with their corresponding theoretical capacities tested for performance
| Sample | Ratio of MPSP:PAN | Theoretical capacity of MPSP (mAhg−1) | Cycles at discharge capacity of 1000 mAhg−1 |
|---|---|---|---|
| 9:1 | 3221 | 30 | |
| 4:1 | 2863 | 170 | |
| 7:3 | 2504 | 170 | |
| 3:2 | 2147 | 123 |
Figure 3(a) Discharge capacity and coulombic efficiency vs.cycle number for sample C (7:3) MPSPs/PPAN composite electrode using a fluorinated (FEC) electrolyte during galvanostatic charge/discharge between 0–1V at constant charge capacity of 1000 mAhg−1 for rate of C/2. Insert shows cycling between 0-1V at constant charge capacity of 1000 mAhg−1 for a rate of C/5. (b) Voltage profiles for sample C (7:3) MPSP/PPAN composite electrode with FEC after 1, 10, 100, 200, 300, 400, 500 and 550 cycles at a rate of C/2 between 0-1 V in half-cells at constant charge capacity of 1000 mAhg−1.
Figure 4(a) Voltage profiles for Sample C (7:3) MPSP/PPAN composite electrode using a non-fluorinated electrolyte after 1, 10, 50, 100, 150 and 170 cycles at a rate of C/5 between 0-1 V in half-cells at constant charge capacity of 1000 mAhg−1.(b) Differential capacity curve for Sample C (7:3) MPSP/PPAN composite electrode in a non-fluorinated electrolyte after 1st and 2nd cycle.