Literature DB >> 23137669

Predictors of in-stent stenosis and occlusion after endovascular treatment of intracranial vascular disease with the Willis covered stent.

Xiao-Biao Lai1, Ming-Hua Li, Hua-Qiao Tan, Ben-Yan Luo, Yue-Qi Zhu, Jue Wang, Yong-Dong Li.   

Abstract

Covered stent placement has emerged as a promising therapeutic option for intracranial vascular lesions. However, in-stent stenosis and occlusion continue to be important concerns with the use of a covered stent, which is more thrombogenic than other types of stents. The purpose of this study was to determine predictors of in-stent stenosis and occlusion for covered stents used in the treatment of intracranial vascular diseases. Clinical, procedural and angiographic data of 46 patients with 49 intracranial vascular lesions treated with the Willis covered stent (Micro-Port, Shanghai, China) between April 2005 and October 2010 were collected and analyzed retrospectively. Univariate analysis and multivariate logistic regression analysis were performed to determine the factors predictive of in-stent stenosis and/or occlusion of the stents. In-stent stenosis and/or occlusion were documented at angiography in six patients with six lesions, and no stenoses or occlusions were seen at angiography in the remaining 40 patients with 43 lesions. Univariate analysis revealed that hypertension, post-procedure irregular antiplatelet therapy and cerebrovascular arteriosclerosis were associated with in-stent stenosis and/or occlusion. By multivariate logistic regression analysis, post-procedure irregular antiplatelet therapy (odds ratio [OR]=15; 95% confidence interval [CI], 1.172-192.004; p=0.037) and cerebrovascular arteriosclerosis (OR=19; 95% CI, 1.374-262.659; p=0.028) were independent predictors of in-stent stenosis and/or occlusion. Thus, post-procedure irregular antiplatelet therapy and coexistent cerebrovascular arteriosclerosis appear to increase the risk of in-stent stenosis and/or occlusion of covered stents in the treatment of intracranial vascular disease.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23137669     DOI: 10.1016/j.jocn.2012.01.051

Source DB:  PubMed          Journal:  J Clin Neurosci        ISSN: 0967-5868            Impact factor:   1.961


  4 in total

1.  In-stent stenosis in the patient with internal carotid aneurysm after treated by the Willis covered stent: Two case reports and literature review.

Authors:  Lun-Xin Liu; Meng-Yuan Song; Xiao-Dong Xie
Journal:  Medicine (Baltimore)       Date:  2017-02       Impact factor: 1.889

2.  Willis Covered Stent for Treating Intracranial Pseudoaneurysms of the Internal Carotid Artery: A Multi-Institutional Study.

Authors:  Dan Lu; Tao Ma; Gemin Zhu; Tao Zhang; Naibing Wang; Hui Lei; Jing Sui; Zhiguo Wang; Shiming He; Lei Chen; Jianping Deng
Journal:  Neuropsychiatr Dis Treat       Date:  2022-01-29       Impact factor: 2.570

Review 3.  Use of covered stents to treat complex cerebrovascular diseases: Expert consensus.

Authors:  Yueqi Zhu; Huaqiao Tan; Zhongxue Wu; Tielin Li; Lianting Ma; Jianmin Liu; Hongqi Zhang; Yuxiang Gu; Tianxiao Li; Sheng Guan; Xiaodong Xie; Chuhan Jiang; Zhenwei Zhao; Chuanzhi Duan; Jieqing Wan; Xiaolong Zhang; Wenfeng Feng; Xuying He; Haibin Shi; Qiujing Wang; Dong Lin; Qiuping Li; Weixi Jiang; Guohua Mao; Shu Zhong; E Chen; Huaizhang Shi; Shaohua Ren; Donghai Wang; Yizhi Liu; Zengpin Liu; Jianliang Wu; Feng Wang; Xuebin Hu; Jun Wang; Fan Zhang; Wenfeng Cao; Donghong Yang; Qingrong Zhang; Lei Wang; Binxian Gu; Guangsen Cheng; Yongcheng Zhang; Chun Fang; Minghua Li
Journal:  Front Cardiovasc Med       Date:  2022-09-16

4.  Blood biomarkers of progressive atherosclerosis and restenosis after stenting of symptomatic intracranial artery stenosis.

Authors:  Melanie Haidegger; Markus Kneihsl; Kurt Niederkorn; Hannes Deutschmann; Harald Mangge; Christian Vetta; Michael Augustin; Gerit Wünsch; Simon Fandler-Höfler; Susanna Horner; Christian Enzinger; Thomas Gattringer
Journal:  Sci Rep       Date:  2021-08-02       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.