| Literature DB >> 23136844 |
Sarah Gordon1, Kaisa Naelapää, Jukka Rantanen, Arzu Selen, Anette Müllertz, Jesper Østergaard.
Abstract
The potential of UV imaging as a new small scale flow-through dissolution testing platform and its ability to incorporate biorelevant media was tested. Furosemide was utilized as a model poorly soluble drug, and dissolution media simulating conditions in the small intestine (5/1.25 mM and 40/10 mM bile salt/phospholipid, pH 6.5) together with corresponding blank buffer were employed. Dissolution rates as a function of flow rate (0.2-1.0 mL/min) were determined directly from UV images, and by analysis of collected effluent using UV spectrophotometry. A good agreement in dissolution rates was observed, however repeatability of data based on measurement of collected effluent was superior to that obtained by UV imaging in the utilized prototypic flow cell. Both methods indicated that biorelevant media did not markedly increase the dissolution rate of furosemide as compared to buffer. Qualitatively, UV images indicated that uncontrolled swelling/precipitation of furosemide on the compact surface was occurring in some samples. In situ Raman spectroscopy together with X-ray diffraction analysis confirmed that the observations were not due to a solid form transformation of furosemide. The presented results highlight the complementary features of the utilized techniques and, in particular, the detailed information related to dissolution behavior which can be achieved by UV imaging.Entities:
Mesh:
Substances:
Year: 2012 PMID: 23136844 DOI: 10.3109/10837450.2012.737808
Source DB: PubMed Journal: Pharm Dev Technol ISSN: 1083-7450 Impact factor: 3.133