Literature DB >> 23134220

Usefulness of dual-time point imaging after carbonated water for the fluorodeoxyglucose positron emission imaging of peritoneal carcinomatosis in colon cancer.

Luca Filippi1, Marco D'Arienzo, Francesco Scopinaro, Rita Salvatori, Oreste Bagni.   

Abstract

BACKGROUND: Fluorodeoxygluose (FDG) positron emission/computed tomography (PET/CT) is emerging as a useful tool for the diagnosis of peritoneal carcinomatosis (PC). In this study, we assessed whether dual-time point imaging can improve the accuracy of FDG PET/CT for the diagnosis of PC after colon rectal cancer (CRC).
METHODS: Thirty-nine patients with past history of CRC were evaluated. Whole-Body PET/CT scan was acquired 1 hour after tracer injection. If one or more focal areas of increased FDG uptake (standardized uptake value, SUV max>2.5) were found in the abdomen, 1 L of carbonated water was orally administered to patients and a delayed scan of the abdominal region was acquired at 2 hours. The SUV max and the mean Delta (Δ) SUV were calculated. The scintigraphic results were compared with the results of colonoscopy and histology and with the clinical follow-up.
RESULTS: Thirteen out of the 39 patients did not show any significant area of FDG uptake at the whole-body scan. The remaining 26 patients showed an overall number of 27 sites of focal increased uptake, showing a mean SUV max of 6.5+3.3. Late scan of the abdomen showed vanishing spots in 11 cases. Focal and increasing FDG uptake was found in 15 subjects (for an overall number of 16 sites) with SUV max of 15.6+4 and mean Δ SUV of +26.3%±7.5%. In these cases, final diagnosis was PC in 10 patients (according to cytology or histology) and dysplastic polyp in 5 cases. No significant difference in Δ SUV was found between patients with PC and those with polypoid formations.
CONCLUSIONS: According to our results, dual-time point imaging after carbonated water may increase the accuracy of FDG PET/CT for the imaging of PC in patients affected by CRC.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23134220     DOI: 10.1089/cbr.2012.1179

Source DB:  PubMed          Journal:  Cancer Biother Radiopharm        ISSN: 1084-9785            Impact factor:   3.099


  3 in total

Review 1.  The role of (18)F-FDG positron emission tomography in the follow-up of liver tumors treated with (90)Yttrium radioembolization.

Authors:  Oreste Bagni; Luca Filippi; Orazio Schillaci
Journal:  Am J Nucl Med Mol Imaging       Date:  2015-02-15

Review 2.  Diagnostic accuracy of 18F-FDG PET/CT for detection of peritoneal carcinomatosis; a systematic review and meta-analysis.

Authors:  Seong-Jang Kim; Sang-Woo Lee
Journal:  Br J Radiol       Date:  2017-11-21       Impact factor: 3.039

Review 3.  Diagnosis and evaluation of gastric cancer by positron emission tomography.

Authors:  Chen-Xi Wu; Zhao-Hui Zhu
Journal:  World J Gastroenterol       Date:  2014-04-28       Impact factor: 5.742

  3 in total