Literature DB >> 23131066

Reduction in inappropriate therapy and mortality through ICD programming.

Arthur J Moss1, Claudio Schuger, Christopher A Beck, Mary W Brown, David S Cannom, James P Daubert, N A Mark Estes, Henry Greenberg, W Jackson Hall, David T Huang, Josef Kautzner, Helmut Klein, Scott McNitt, Brian Olshansky, Morio Shoda, David Wilber, Wojciech Zareba.   

Abstract

BACKGROUND: The implantable cardioverter-defibrillator (ICD) is highly effective in reducing mortality among patients at risk for fatal arrhythmias, but inappropriate ICD activations are frequent, with potential adverse effects.
METHODS: We randomly assigned 1500 patients with a primary-prevention indication to receive an ICD with one of three programming configurations. The primary objective was to determine whether programmed high-rate therapy (with a 2.5-second delay before the initiation of therapy at a heart rate of ≥200 beats per minute) or delayed therapy (with a 60-second delay at 170 to 199 beats per minute, a 12-second delay at 200 to 249 beats per minute, and a 2.5-second delay at ≥250 beats per minute) was associated with a decrease in the number of patients with a first occurrence of inappropriate antitachycardia pacing or shocks, as compared with conventional programming (with a 2.5-second delay at 170 to 199 beats per minute and a 1.0-second delay at ≥200 beats per minute).
RESULTS: During an average follow-up of 1.4 years, high-rate therapy and delayed ICD therapy, as compared with conventional device programming, were associated with reductions in a first occurrence of inappropriate therapy (hazard ratio with high-rate therapy vs. conventional therapy, 0.21; 95% confidence interval [CI], 0.13 to 0.34; P<0.001; hazard ratio with delayed therapy vs. conventional therapy, 0.24; 95% CI, 0.15 to 0.40; P<0.001) and reductions in all-cause mortality (hazard ratio with high-rate therapy vs. conventional therapy, 0.45; 95% CI, 0.24 to 0.85; P=0.01; hazard ratio with delayed therapy vs. conventional therapy, 0.56; 95% CI, 0.30 to 1.02; P=0.06). There were no significant differences in procedure-related adverse events among the three treatment groups.
CONCLUSIONS: Programming of ICD therapies for tachyarrhythmias of 200 beats per minute or higher or with a prolonged delay in therapy at 170 beats per minute or higher, as compared with conventional programming, was associated with reductions in inappropriate therapy and all-cause mortality during long-term follow-up. (Funded by Boston Scientific; MADIT-RIT ClinicalTrials.gov number, NCT00947310.).

Entities:  

Mesh:

Year:  2012        PMID: 23131066     DOI: 10.1056/NEJMoa1211107

Source DB:  PubMed          Journal:  N Engl J Med        ISSN: 0028-4793            Impact factor:   91.245


  248 in total

1.  [Lead survival and complications (except infections). Are we doing better nowadays?].

Authors:  Martin Seifert; Michael Neuss; Maren Schöpp; Cornel Koban; Christian Butter
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2013-08-06

Review 2.  A translational approach to probe the proarrhythmic potential of cardiac alternans: a reversible overture to arrhythmogenesis?

Authors:  Faisal M Merchant; Omid Sayadi; Dheeraj Puppala; Kasra Moazzami; Victoria Heller; Antonis A Armoundas
Journal:  Am J Physiol Heart Circ Physiol       Date:  2013-12-06       Impact factor: 4.733

3.  Mitigating Post-Extraction Risk: Is it Worth the inVESTment?

Authors:  Mina K Chung
Journal:  JACC Clin Electrophysiol       Date:  2016-12-21

Review 4.  ICD programming to reduce shocks and improve outcomes.

Authors:  Valentina Kutyifa; Wojciech Zareba; Arthur J Moss
Journal:  Curr Cardiol Rep       Date:  2014       Impact factor: 2.931

5.  For Whom the Bell Tolls : Refining Risk Assessment for Sudden Cardiac Death.

Authors:  Ivaylo Tonchev; David Luria; David Orenstein; Chaim Lotan; Yitschak Biton
Journal:  Curr Cardiol Rep       Date:  2019-08-02       Impact factor: 2.931

Review 6.  A combined anatomic and electrophysiologic substrate based approach for sudden cardiac death risk stratification.

Authors:  Faisal M Merchant; Hui Zheng; Thomas Bigger; Richard Steinman; Takanori Ikeda; Roberto F E Pedretti; Jorge A Salerno-Uriarte; Catherine Klersy; Paul S Chan; Cheryl Bartone; Stefan H Hohnloser; Jeremy N Ruskin; Antonis A Armoundas
Journal:  Am Heart J       Date:  2013-09-18       Impact factor: 4.749

7.  National experience with long-term use of the wearable cardioverter defibrillator in patients with cardiomyopathy.

Authors:  Madhab Lamichhane; Joseph C Gardiner; Nicole R Bianco; Steven J Szymkiewicz; Ranjan K Thakur
Journal:  J Interv Card Electrophysiol       Date:  2016-10-17       Impact factor: 1.900

Review 8.  Ventricular Tachycardia with ICD Shocks: When to Medicate and When to Ablate.

Authors:  Amir AbdelWahab; John Sapp
Journal:  Curr Cardiol Rep       Date:  2017-09-13       Impact factor: 2.931

Review 9.  Optimal tachycardia programming in ICDs : Recommendations in the post-MADIT-RIT era.

Authors:  Carsten W Israel; Tatsiana Burmistrava
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2016-09

10.  Effect of cardiac resynchronization therapy on the risk of ventricular tachyarrhythmias in patients with chronic kidney disease.

Authors:  Usama A Daimee; Yitschak Biton; Arthur J Moss; Wojciech Zareba; David Cannom; Helmut Klein; Scott Solomon; Martin H Ruwald; Scott McNitt; Bronislava Polonsky; Paul J Wang; Ilan Goldenberg; Valentina Kutyifa
Journal:  Ann Noninvasive Electrocardiol       Date:  2016-09-15       Impact factor: 1.468

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.