Literature DB >> 23127920

Ovarian responses and pregnancy rate with previously used intravaginal progesterone releasing devices for fixed-time artificial insemination in sheep.

M Vilariño1, E Rubianes, A Menchaca.   

Abstract

The objective was to determine serum progesterone concentrations, ovarian responses, and pregnancy rate in sheep inseminated following a short-term protocol (6 days of treatment) with a previously used controlled internal drug release-G (CIDR-G) device. In experiment 1, 30 ewes were put on a short-term protocol using a CIDR-G of first use (new devices, N = 10), second use (previously used for 6 days, N = 10), or third use (previously used twice for 6 days, N = 10). All ewes were given prostaglandin F(2α) (10 mg dinoprost) and eCG (300 IU) im at device withdrawal. Mean serum progesterone concentrations were greater for ewes treated with new versus reused devices (P < 0.05), but there were no significant effects on ovarian follicular development, namely: proportion of ewes that reached ovulation/treated ewes (8/10, 9/10, and 10/10); day of emergence of the ovulatory follicle (2.9 ± 1.8, 1.8 ± 2.4, and 2.5 ± 1.1 days after CIDR-G insertion); and lifespan of the ovulatory follicle (5.4 ± 1.8, 6.5 ± 2.2, and 5.6 ± 1.0 days) for devices of first, second, and third use, respectively. The proportion of ewes that ovulated from a new follicle emerging after CIDR-G insertion was 100% (10/10) with new devices, and 77.8% (7/9) and 80% (8/10) with devices used two and three times, respectively (P = not significant). In experiment 2, ewes (N = 319) received the short-term protocol as in experiment 1, using CIDR-G of first or third use (N = 158 and N = 161, respectively) for 6 days, with prostaglandin F(2α) and eCG given im at device withdrawal. Intrauterine (laparoscopy) fixed-time AI with fresh semen (100 × 10(6) sperm) was done 52 to 57 hours after device withdrawal. Pregnancy rates were 80.4% (127/158) and 71.4% (115/161) for devices of first and third use, respectively (P = 0.06). We concluded that the CIDR-G with short-term protocol was effective for estrous synchronization and ovulation, with lower serum progesterone concentrations for reused devices. Three times used CIDR-G yielded a pregnancy rate >70%, which tended to be lower than that obtained with new devices, adding evidence of the detrimental effect of low serum progesterone concentrations on fertility in sheep.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23127920     DOI: 10.1016/j.theriogenology.2012.10.007

Source DB:  PubMed          Journal:  Theriogenology        ISSN: 0093-691X            Impact factor:   2.740


  4 in total

1.  The reused progesterone device has the same effect on short or long estrus synchronization protocols in tropical sheep.

Authors:  Marcos Vinicius Biehl; Marcos Vinicius Castro de Ferraz Junior; José Paulo Roman Barroso; Ivanete Susin; Evandro Maia Ferreira; Daniel Montanher Polizel; Alexandre Vaz Pires
Journal:  Trop Anim Health Prod       Date:  2019-02-19       Impact factor: 1.559

2.  Estrous and ovulatory responses following cervical artificial insemination in Thai-native goats given a new or once-used controlled internal drug release with human chorionic gonadotropin.

Authors:  Chainarong Navanukraw; Vilaivan Khanthusaeng; Aree Kraisoon; Suthipong Uriyapongson
Journal:  Trop Anim Health Prod       Date:  2014-09-12       Impact factor: 1.559

3.  From reproductive technologies to genome editing in small ruminants: an embryo's journey.

Authors:  Alejo Menchaca; Pedro C Dos Santos-Neto; Frederico Cuadro; Marcela Souza-Neves; Martina Crispo
Journal:  Anim Reprod       Date:  2018-08-03       Impact factor: 1.810

4.  Effects of progestagen exposure duration on estrus synchronization and conception rates of crossbreed ewes undergoing fixed time artificial insemination.

Authors:  Wanessa Blaschi; Paula A Lunardelli; Luciana S R Marinho; Marilu C Max; Gustavo M G Santos; Katia C Silva-Santos; Fabiana A Melo-Sterza; Hernan Baldassarre; Thales R Rigo; Marcelo M Seneda
Journal:  J Vet Sci       Date:  2014-06-20       Impact factor: 1.672

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.