Literature DB >> 23127449

Template-directed instrumentation in total knee arthroplasty: cost savings analysis.

Andrew R Hsu1, Christopher E Gross, Sanjeev Bhatia, Brett R Levine.   

Abstract

The use of digital radiography and templating software in total knee arthroplasty (TKA) continues to become more prevalent as the number of procedures performed increases every year. Template-directed instrumentation (TDI) is a novel approach to surgical planning that combines digital templating with limited intraoperative instruments. The purpose of this study was to evaluate the financial implications and radiographic outcomes of using TDI to direct instrumentation during primary TKA. Over a 1-year period, 82 consecutive TKAs using TDI were retrospectively reviewed. Patient demographics and preoperative templated sizes of predicted components were recorded, and OrthoView digital planning software (OrthoView LLC, Jacksonville, Florida was used to determine the 2 most likely tibial and femoral component sizes for each case. This sizing information was used to direct component vendors to prepare 3 lightweight instrument trays based on these sizes. The sizes of implanted components and the number of total trays required were documented. A cost savings analysis was performed to compare TDI and non-TDI surgical expenses for TKA. In 80 (97%) of 82 cases, the prepared sizes determined by TDI using 3 instrument trays were sufficient. Preoperative templating correctly predicted the size of the tibial and femoral component sizes in 90% and 83% of cases, respectively. The average number of trays used with TDI was 3.0 (range, 3-5 trays) compared with 7.5 (range, 6-9 trays) used in 82 preceding non-TDI TKAs. Based on standard fees to sterilize and package implant trays (approximately $26 based on a survey of 10 orthopedic hospitals performing TKA), approximately $9612 was saved by using TDI over the 1-year study period. Overall, digital templating and TDI were a simple and cost-effective approach when performing primary TKA. Copyright 2012, SLACK Incorporated.

Entities:  

Mesh:

Year:  2012        PMID: 23127449     DOI: 10.3928/01477447-20121023-15

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  10 in total

1.  Pre-operative templating for knee arthroplasty shows low accuracy with standard X-rays.

Authors:  Nelson Hiroyuki Miyabe Ooka; André Luiz Siqueira Campos; Vitor Mudesto da Fonseca; Luis Edmundo Oliveira Rodrigues; Edmilson Barbosa Filho; José Sérgio Franco; Rodrigo Satamini Pires E Albuquerque; Vinicius Schott Gameiro
Journal:  Int Orthop       Date:  2018-01-15       Impact factor: 3.075

2.  Preoperative radiographic parameters in the case of using a narrow-version femoral implant in total knee arthroplasty.

Authors:  Jaehyun Kim; Seongyun Park; Ji Hyun Ahn
Journal:  Arch Orthop Trauma Surg       Date:  2021-08-17       Impact factor: 2.928

3.  The use of preoperative planning to decrease costs and increase efficiency in the OR.

Authors:  Bhavya Sheth; Alessia C Lavin; Christian Martinez; Vani J Sabesan
Journal:  JSES Int       Date:  2022-02-25

4.  Implementing a perioperative efficiency initiative for orthopedic surgery instrumentation at an academic center: A comparative before-and-after study.

Authors:  Richard Capra; Stefano A Bini; Dawn E Bowden; Katherine Etter; Matt Callahan; Richard T Smith; Thomas Parker Vail
Journal:  Medicine (Baltimore)       Date:  2019-02       Impact factor: 1.817

5.  Accuracy of one-dimensional templating on linear EOS radiography allows template-directed instrumentation in total knee arthroplasty.

Authors:  Michael Andreas Finsterwald; Salar Sobhi; Senthuren Isaac; Penelope Scott; Riaz J K Khan; Daniel P Fick
Journal:  J Orthop Surg Res       Date:  2021-11-10       Impact factor: 2.359

6.  Scaling Marker Position Determines the Accuracy of Digital Templating for Total Hip Arthroplasty.

Authors:  Austin J Ramme; Nina D Fisher; Jonathan Egol; Gregory Chang; Jonathan M Vigdorchik
Journal:  HSS J       Date:  2017-09-12

7.  Machine Learning Predicts Femoral and Tibial Implant Size Mismatch for Total Knee Arthroplasty.

Authors:  Evan M Polce; Kyle N Kunze; Katlynn M Paul; Brett R Levine
Journal:  Arthroplast Today       Date:  2021-02-26

8.  Agreement in component size between preoperative measurement, navigation and final implant in total knee replacement.

Authors:  Daniel Hernández-Vaquero; Alfonso Noriega-Fernandez; Sergio Roncero-Gonzalez; Ivan Perez-Coto; Andres A Sierra-Pereira; Manuel A Sandoval-Garcia
Journal:  J Orthop Translat       Date:  2018-11-22       Impact factor: 5.191

9.  Employee Acceptance of Use: A Precondition for Enhancing Therapy Effectiveness, Patient Safety, and Economic Efficiency.

Authors:  Maximilian C von Eiff; Wilfried von Eiff; Andreas Roth; Mohamed Ghanem
Journal:  Front Public Health       Date:  2019-12-05

Review 10.  Approaches to the rationalization of surgical instrument trays: scoping review and research agenda.

Authors:  Bruno Miranda Dos Santos; Flavio Sanson Fogliatto; Carolina Melecardi Zani; Fernanda Araujo Pimentel Peres
Journal:  BMC Health Serv Res       Date:  2021-02-20       Impact factor: 2.655

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.