Literature DB >> 2312198

A spectral analysis of the high frequency QRS potentials observed during acute myocardial ischemia in dogs.

S Abboud1, R J Cohen, D Sadeh.   

Abstract

Electrocardiographic manifestations of transient myocardial ischemia were studied in 10 dogs undergoing occlusion of the left anterior descending coronary artery, using frequency domain analysis of the high frequency QRS potentials. Ischemia was induced via a balloon occluding cuff placed around the coronary artery. Electrocardiographic waveforms recorded before and during the ischemic state were averaged together and then filtered between 150 and 250 Hz to obtain the high frequency QRS complex. The spectral curve in the power spectrum of the high frequency QRS components was calculated using an algorithm for fast Fourier transformation. Balloon inflation was accompanied by morphological changes in the spectral curve in 7 of 10 experiments. Morphological changes, seen as zones of reduced amplitude in the time domain, appear as two separate peaks in the frequency domain. These changes were seen early in ischemia and were not accompanied by significant changes in the QRS complex or ST segment of the conventional surface electrocardiogram. The power spectrum of the high-frequency QRS potentials appears to detect evidence of transient ischemia and may provide useful information regarding the presence of myocardial ischemia.

Entities:  

Mesh:

Year:  1990        PMID: 2312198     DOI: 10.1016/0167-5273(90)90084-i

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  3 in total

1.  Characterisation of acute myocardial ischaemia in a canine model based on principal component analysis of unipolar endocardial electrograms.

Authors:  A Schwartzman; T Wolf; L Gepstein; G Hayam; J Lessick; D Reisfeld; Y Schwartz; G Uretzky; S A Ben-Haim
Journal:  Med Biol Eng Comput       Date:  2001-09       Impact factor: 2.602

2.  Improved detection of ischemic heart disease by combining high-frequency electrocardiogram analysis with exercise stress echocardiography.

Authors:  Jin-Oh Choi; Sung-A Chang; Sung Ji Park; Sang-Chol Lee; Seung Woo Park
Journal:  Korean Circ J       Date:  2013-10-30       Impact factor: 3.243

3.  A novel method to capture the onset of dynamic electrocardiographic ischemic changes and its implications to arrhythmia susceptibility.

Authors:  Omid Sayadi; Dheeraj Puppala; Nosheen Ishaque; Rajiv Doddamani; Faisal M Merchant; Conor Barrett; Jagmeet P Singh; E Kevin Heist; Theofanie Mela; Juan Pablo Martínez; Pablo Laguna; Antonis A Armoundas
Journal:  J Am Heart Assoc       Date:  2014-09-03       Impact factor: 5.501