Literature DB >> 23121322

Tracheal intubation with a camera embedded in the tube tip (Vivasight(™) ).

J M Huitink1, E M Koopman, R A Bouwman, A Craenen, M Verwoert, R Krage, I E Visser, M Erwteman, D van Groeningen, R Tijink, A Schauer.   

Abstract

We studied tracheal intubation in manikins and patients with a camera embedded in the tip of the tracheal tube (Vivasight(™) ). Four people in two teams and two individuals attempted intubation of a manikin through an i-gel(™) 10 times each. The tracheas of 12 patients with a Mallampati grade of 1 were intubated with a Vivasight tracheal tube through a Berman airway, passed over a Frova(™) introducer. All 60 manikin intubations were successful, taking a mean (SD) time of 1.4 (0.5) s. The fastest intubation was performed in 0.5 s. All 12 participants' tracheas were successfully intubated in a median (IQR [range]) time of 90 (70-120 [50-210]) s. Seven participants complained of a sore throat, comparable with earlier findings for standard laryngoscopy and intubation: five mild; one moderate; and one severe. Tracheal intubation with the Vivasight through the i-gel or Berman airway is an alternative to existing techniques, against which it should be compared in randomised controlled trials in human participants. It has potential as a fast airway rescue technique. Anaesthesia
© 2012 The Association of Anaesthetists of Great Britain and Ireland.

Entities:  

Mesh:

Year:  2012        PMID: 23121322     DOI: 10.1111/anae.12065

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  6 in total

1.  A novel airway device with tactile sensing capabilities for verifying correct endotracheal tube placement.

Authors:  Pauwel Goethals; Harshu Chaobal; Dominiek Reynaerts; David Schaner
Journal:  J Clin Monit Comput       Date:  2013-09-25       Impact factor: 2.502

2.  Bronchoscopy versus an endotracheal tube mounted camera for the peri-interventional visualization of percutaneous dilatational tracheostomy - a prospective, randomized trial (VivaPDT).

Authors:  Jörn Grensemann; Lars Eichler; Sophie Kähler; Dominik Jarczak; Marcel Simon; Hans O Pinnschmidt; Stefan Kluge
Journal:  Crit Care       Date:  2017-12-29       Impact factor: 9.097

3.  An original design of remote robot-assisted intubation system.

Authors:  Xinyu Wang; Yuanfa Tao; Xiandong Tao; Jianglong Chen; Yifeng Jin; Zhengxiang Shan; Jiyang Tan; Qixin Cao; Tiewen Pan
Journal:  Sci Rep       Date:  2018-09-07       Impact factor: 4.379

4.  Tracheal Tube-Mounted Camera Assisted Intubation vs. Videolaryngoscopy in Expected Difficult Airway: A Prospective, Randomized Trial (VivaOP Trial).

Authors:  Jörn Grensemann; Emma Möhlenkamp; Philipp Breitfeld; Pischtaz A Tariparast; Tanja Peters; Mark A Punke; Stefan Kluge; Martin Petzoldt
Journal:  Front Med (Lausanne)       Date:  2021-12-15

5.  The use of VivaSight™ single lumen endotracheal tube in morbidly obese patients undergoing laparoscopic sleeve gastrectomy.

Authors:  Michal Barak; Ahmad Assalia; Ahmad Mahajna; Bishara Bishara; Alexander Braginski; Yoram Kluger
Journal:  BMC Anesthesiol       Date:  2014-05-05       Impact factor: 2.217

6.  Endotracheal tube-mounted camera-assisted intubation versus conventional intubation in intensive care: a prospective, randomised trial (VivaITN).

Authors:  Jörn Grensemann; Lars Eichler; Nuowei Wang; Dominik Jarczak; Marcel Simon; Stefan Kluge
Journal:  Crit Care       Date:  2018-09-22       Impact factor: 9.097

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.