Literature DB >> 23112038

Smaller incision size leads to higher predictability in microcoaxial cataract surgery.

Matthias K J Klamann1, Johannes Gonnermann, Anna-Karina B Maier, Necip Torun, Eckart Bertelmann.   

Abstract

PURPOSE: The aim of the study was to compare the clinical outcomes of a 1.8 mm, 2.2 mm, and 2.75 mm microcoaxial cataract surgery system. METHODS. In this retrospective study, 129 eyes of 129 patients were included. Patients underwent phacoemulsification using a Stellaris system or an Infiniti system. The incision size was 1.8 mm, 2.2 mm, or 2.75 mm, respectively. Subjects were examined before surgery and 4 weeks after. The surgically induced astigmatism (SIA) was examined.
RESULTS: The SIA in the 1.8 mm group was statistically lower compared to the 2.2 mm group (p=0.046) and the 2.75 mm group (p=0.017). There was no significant difference between the 2.2 mm group and the 2.75 mm group.
CONCLUSIONS: With the use of appropriate support systems, 1.8 mm incisions appear to result in less SIA than 2.2 mm and 2.75 mm incisions. Advantages may arise from this, especially in the implantation of aspheric, toric, or multifocal lenses.

Entities:  

Mesh:

Year:  2013        PMID: 23112038     DOI: 10.5301/ejo.5000207

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  5 in total

1.  Pivot concept: achieving a good-quality capsulorrhexis through a 2.2 mm or less clear corneal incision by using standard capsulorhexis forceps.

Authors:  Hung-Yuan Lin; Ya-Jung Chuang; Xin Tang; Chun-Chang Lin; Hsin-Yang Chen; Pi-Jung Lin
Journal:  Int J Ophthalmol       Date:  2017-07-18       Impact factor: 1.779

2.  Incidence of cystoid macular edema with iris-fixated posterior chamber intraocular lenses in patients presenting with lens dislocation.

Authors:  Irene Rusu; Zhe Chen; Jessica Zizva; Jane S Myung; Kenneth J Wald
Journal:  Int Ophthalmol       Date:  2014-07-25       Impact factor: 2.031

3.  A comparable study of clinical and optical outcomes after 1.8, 2.0 mm microcoaxial and 3.0 mm coaxial cataract surgery.

Authors:  Yi-Bo Yu; Ya-Nan Zhu; Wei Wang; Yi-Dong Zhang; Yin-Hui Yu; Ke Yao
Journal:  Int J Ophthalmol       Date:  2016-03-18       Impact factor: 1.779

4.  Long-term clinical outcomes obtained with bilateral implantation of a multifocal intraocular lens through two different-sized corneal incisions.

Authors:  Efthymios Karmiris; Evangelia Chalkiadaki; Evangelia Papakonstantinou; Ilias Georgalas
Journal:  Saudi J Ophthalmol       Date:  2022-08-29

5.  Coaxial Microincision Cataract Surgery versus Standard Coaxial Small-Incision Cataract Surgery: A Meta-Analysis of Randomized Controlled Trials.

Authors:  Xingchao Shentu; Xin Zhang; Xiajing Tang; Xiaoning Yu
Journal:  PLoS One       Date:  2016-01-08       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.