Literature DB >> 23111968

The influence of smoking and surgical technique on the accuracy of mucosa-supported stereolithographic surgical guide in complete edentulous upper jaws.

M Cassetta1, G Pompa, S Di Carlo, L Piccoli, A Pacifici, L Pacifici.   

Abstract

BACKGROUND: The accuracy of a stereolithographic surgical guide depends on several variables that can affect at any time from the software-planning stage to the surgical field. AIM: The purpose of this study was to evaluate the accuracy of implants inserted using a single mucosa-supported stereolithographic surgical guide determining also the influence of surgical technique (fixed and not-fixed) and smoking on the deviation parameters.
MATERIALS AND METHODS: 11 patients, totally edentate in the upper arch and needed an implant-prosthetic rehabilitation, were selected. 95 implants were planned and inserted. The pre- and post-operative CT images were compared using software.
RESULTS: Global, coronal (Mean: 1.65; Range: 3.00-0.13; SD:0.56) and apical (Mean: 2.15; Range: 4.23-0.34; SD:0.81), and angular (Mean: 4.62; Range: 15.25-0.28; SD: 2.74) deviation values were determined. The mean values of mucosa thickness in smokers and nonsmokers patients were 4.53 mm and 3.42 mm respectively (p < .05). The accuracy data showed a better result for the angular deviation when the surgical template was fixed (p = .002) and a better global apical deviation in the nonsmokers (p <. 05).
CONCLUSIONS: It is essential, especially in smoker patients, to respect a minimum safety distance of 3 mm from limiting anatomic structures.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23111968

Source DB:  PubMed          Journal:  Eur Rev Med Pharmacol Sci        ISSN: 1128-3602            Impact factor:   3.507


  3 in total

1.  Dental Implants Placed in Patients with Mechanical Risk Factors: A Long-term Follow-up Retrospective Study.

Authors:  Piero Papi; Stefano Di Carlo; Francesca Mencio; Daniele Rosella; Francesca De Angelis; Giorgio Pompa
Journal:  J Int Soc Prev Community Dent       Date:  2017-06-20

Review 2.  Accuracy of Guided Surgery via Stereolithographic Mucosa-Supported Surgical Guide in Implant Surgery for Edentulous Patient: a Systematic Review.

Authors:  Cheongbeom Seo; Gintaras Juodzbalys
Journal:  J Oral Maxillofac Res       Date:  2018-03-31

Review 3.  Accuracy of Computer-Assisted Flapless Implant Placement by Means of Mucosa-Supported Templates in Complete-Arch Restorations: A Systematic Review.

Authors:  Paolo Carosi; Claudia Lorenzi; Fabrizio Lio; Pierluigi Cardelli; Alessandro Pinto; Andrea Laureti; Alessandro Pozzi
Journal:  Materials (Basel)       Date:  2022-02-16       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.