Literature DB >> 2311144

Risk of cross-infection related to the multiple use of disposable syringes.

C A Trépanier1, M R Lessard, J G Brochu, P H Denault.   

Abstract

The rate of blood contamination of IV tubings used in anaesthesia practice was investigated. Only IV tubings started in the operating room were studied. First, 300 tubings of three different types were tested at the three distal injection sites. The contamination rate was 3.3 per cent at the injection site closest to the IV catheter and 0.3 per cent at the furthest. The presence of a check-valve did not affect the contamination rate. Second, 300 third injection sites fixed at a level equal to or above the IV catheter were tested. None of them was contaminated. Finally, in order to evaluate whether changing the needle alone could prevent the contamination of syringes, injections were made into a tubing where blood was flowing. Thirty-four per cent of the syringes tested positive for blood. We conclude that IV tubings have a significant contamination rate in usual practice. This rate decreases as the distance from the IV catheter increases. The use of the third site fixed at a level equal to or above the IV catheter carries a lower risk of contamination. Changing the needle alone is a useless procedure to prevent cross-contamination.

Entities:  

Mesh:

Year:  1990        PMID: 2311144     DOI: 10.1007/BF03005462

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  9 in total

1.  Recommendations for prevention of HIV transmission in health-care settings.

Authors: 
Journal:  MMWR Suppl       Date:  1987-08-21

2.  HIV-1 infections in the Canadian Atlantic provinces.

Authors:  K R Rozee; S H Lee; C Swantee
Journal:  Can Dis Wkly Rep       Date:  1988-06-25

3.  Serodiagnosis of HIV in Manitoba.

Authors:  L H Sekla; G Hammond; J Stackiw; G Eibisch
Journal:  Can Dis Wkly Rep       Date:  1988-01-16

4.  A microbiological study of the contamination of the syringes used in anaesthesia practice.

Authors:  M R Lessard; C A Trépanier; M Gourdeau; P H Denault
Journal:  Can J Anaesth       Date:  1988-11       Impact factor: 5.063

5.  Allergy testing of multiple patients should no longer be performed with a common syringe.

Authors:  C T Lutz; C E Bell; H J Wedner; D J Krogstad
Journal:  N Engl J Med       Date:  1984-05-17       Impact factor: 91.245

6.  Should all pregnant women be screened for hepatitis B?

Authors:  M L Kumar; N V Dawson; A J McCullough; M Radivoyevitch; K C King; R Hertz; H Kiefer; M Hampson; R Cassidy; A S Tavill
Journal:  Ann Intern Med       Date:  1987-09       Impact factor: 25.391

7.  Universal prenatal screening for hepatitis B, Alberta, 1985-1988.

Authors:  J R Waters
Journal:  Can Dis Wkly Rep       Date:  1989-02-11

Review 8.  Occupational infection with human immunodeficiency virus (HIV). Risks and risk reduction.

Authors:  C E Becker; J E Cone; J Gerberding
Journal:  Ann Intern Med       Date:  1989-04-15       Impact factor: 25.391

9.  Infectious diseases and the anaesthetist.

Authors:  R A Browne; M A Chernesky
Journal:  Can J Anaesth       Date:  1988-11       Impact factor: 5.063

  9 in total
  11 in total

Review 1.  Transmission of hepatitis and AIDS: risks for the anaesthetist and the patient.

Authors:  C A Trépanier
Journal:  Can J Anaesth       Date:  1991-05       Impact factor: 5.063

Review 2.  Current issues in endoscope reprocessing and infection control during gastrointestinal endoscopy.

Authors:  Douglas B Nelson; Lawrence F Muscarella
Journal:  World J Gastroenterol       Date:  2006-07-07       Impact factor: 5.742

3.  Reconstituted thiopentone retains its alkalinity without bacterial contamination for up to four weeks.

Authors:  C L Wong; C B Warriner; J P McCormack; A M Clarke
Journal:  Can J Anaesth       Date:  1992-05       Impact factor: 5.063

4.  Anaesthesia drug cost, control and utilization in Canada.

Authors:  G S Kantor; F Chung
Journal:  Can J Anaesth       Date:  1996-01       Impact factor: 5.063

5.  Anaesthesia drug costs and utilization--time for a critical re-appraisal.

Authors:  D R Miller
Journal:  Can J Anaesth       Date:  1996-01       Impact factor: 5.063

6.  Reuse of syringes in anaesthesia practice.

Authors:  G B Skidmore
Journal:  Can J Anaesth       Date:  1996-04       Impact factor: 5.063

7.  Do "Venflon" sideport valves leak?

Authors:  I R Selby; J P Kavanagh
Journal:  Can J Anaesth       Date:  1996-07       Impact factor: 5.063

Review 8.  Hepatitis C virus screening and management of seroconversions in hemodialysis facilities.

Authors:  Chukwuma Mbaeyi; Nicola D Thompson
Journal:  Semin Dial       Date:  2013-05-31       Impact factor: 3.455

9.  Uncovering high rates of unsafe injection equipment reuse in rural Cameroon: validation of a survey instrument that probes for specific misconceptions.

Authors:  Mbah P Okwen; Bedes Y Ngem; Fozao A Alomba; Mireille V Capo; Savanna R Reid; Ebong C Ewang
Journal:  Harm Reduct J       Date:  2011-02-07

10.  Anaesthetic considerations for the hiv positive parturient.

Authors:  Adesina Oluwabukola; Oladokun Adesina
Journal:  Ann Ib Postgrad Med       Date:  2009-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.