Literature DB >> 23110854

Implantable cardioverter defibrillator shocks are prospective predictors of anxiety.

Stefan M Schulz1, Claudia Massa, Anna Grzbiela, Wilhelm Dengler, Georg Wiedemann, Paul Pauli.   

Abstract

OBJECTIVES: To examine the temporal contingency of anxiety and implantable cardioverter defibrillator (ICD) therapy (anti-tachycardia-pacing and shocks to prevent ventricular tachycardia and/or fibrillation).
BACKGROUND: It is under debate whether anxiety is a precursor and/or consequence of ICD-therapy.
METHODS: In a prospective longitudinal study, fifty-four patients undergoing first-time ICD-implantation were assessed for anxiety, frequency of ICD-shocks and anti-tachycardia-pacing up to two days before ICD-implantation (T0) and twelve months later (T1).
RESULTS: Anxiety at T0 did not predict frequency of ICD-shocks at T1, but ICD-shocks significantly predicted increased anxiety at T1. In contrast, anxiety at T0 and T1 was unrelated to frequency of anti-tachycardia-pacing. Effects remained stable when we controlled for potentially confounding variables (e.g. age, sex, cardiac health and depression at T0).
CONCLUSION: Our findings indicate that repeated ICD-shocks are a cause of anxiety in ICD-patients rather than a consequence, thus shock frequency should be minimized.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23110854     DOI: 10.1016/j.hrtlng.2012.08.006

Source DB:  PubMed          Journal:  Heart Lung        ISSN: 0147-9563            Impact factor:   2.210


  3 in total

1.  Reduction of inappropriate implantable cardioverter-defibrillator therapies using enhanced supraventricular tachycardia discriminators: the ReduceIT study.

Authors:  Johann Christoph Geller; Armin Wöhrle; Mathias Busch; Albrecht Elsässer; Thomas Kleemann; Frank Birkenhauer; Peter Bramlage; Christian Veltmann
Journal:  J Interv Card Electrophysiol       Date:  2020-07-14       Impact factor: 1.900

2.  The Significance of Shocks in Implantable Cardioverter Defibrillator Recipients.

Authors:  Anthony Li; Amit Kaura; Nicholas Sunderland; Paramdeep S Dhillon; Paul A Scott
Journal:  Arrhythm Electrophysiol Rev       Date:  2016-08

3.  The Value of the Tei Index in Predicting Implantable Cardioverter Defibrillator Shocks.

Authors:  Sabri Seyis
Journal:  Sisli Etfal Hastan Tip Bul       Date:  2018-03-14
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.