Literature DB >> 23110581

Two-year interfacial bond durability and nanoleakage of repaired silorane-based resin composite.

E Mobarak1, H El-Deeb.   

Abstract

OBJECTIVES: To investigate the effect of silane primer application, intermediate adhesive agent/repair composite, and storage period on the interfacial microtensile bond strength (μTBS) of repaired silorane-based resin composite compared with unrepaired composites and on the nanoleakage.
METHODS: Forty-eight 1-month-old substrate specimens from Filtek P90 were roughened, etched, and distributed over two groups (n=24) based on receiving silane (Clearfil Ceramic Primer) or not. Then, half of the specimens (n=12) were repaired with P90 System Adhesive/Filtek P90 and the other half with Adper Scotchbond Multipurpose adhesive/Filtek Z250 resin composite. Within each repair category, repaired specimens were stored in artificial saliva at 37°C for either 24 hours (n=6) or two years before being serially sectioned into sticks (0.6 ± 0.01 mm(2)). From each specimen, two sticks were prepared for nanoleakage determination and four sticks were used for μTBS testing. Additional unrepaired specimens from each composite (n=12) were made to determine the cohesive strength at 24 hours and two years. Mean μTBS were calculated and statistically analyzed. Modes of failure were also determined.
RESULTS: General linear model analysis revealed no significant effect for the silane priming, intermediate adhesive agent/repair composite, and storage period or for their interactions on the μTBS values of the repaired specimens. There was no significant difference between the cohesive strength of Filtek P90 and Filtek Z250; both were significantly higher than all repaired categories. At 24 hours, nanoleakage was not detected when silorane-based composite was repaired with the same material. However, after two years, all repair categories showed nanoleakage.
CONCLUSIONS: Silane application has no effect on μTBS and nanoleakage. Durability of the interfacial bond of repaired silorane-based resin composite appeared successful regardless of the chemistry of the intermediate adhesive agent/composite used for repair. However, nanoleakage was detected early when a different repair intermediate adhesive agent/composite was used.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23110581     DOI: 10.2341/12-061-L

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  5 in total

1.  Repair bond strength of dual-cured resin composite core buildup materials.

Authors:  Heba A El-Deeb; Radwa M Ghalab; Mai M Elsayed Akah; Enas H Mobarak
Journal:  J Adv Res       Date:  2015-06-20       Impact factor: 10.479

2.  Reparability of giomer using different mechanical surface treatments.

Authors:  Saba Arami; Soodabeh Kimyai; Parnian-Alizadeh Oskoee; Mehdi Daneshpooy; Sahand Rikhtegaran; Mahmoud Bahari; Mehdi-Abed Kahnamoii
Journal:  J Clin Exp Dent       Date:  2017-04-01

3.  Repair bond strength of bulk fill composites after different adhesion protocols.

Authors:  Thiago-Clístines de Medeiros; Mariana-Rodrigues de Lima; Stephany-Cimarosti-Figueiredo Bessa; Diana-Ferreira-Gadelha de Araújo; Marília-Regalado Galvão
Journal:  J Clin Exp Dent       Date:  2019-11-01

4.  Influence of commercial adhesive with/without silane on the bond strength of resin-based composite repaired within twenty-four hours.

Authors:  Ker-Kong Chen; Jeng-Huey Chen; Ju-Hui Wu; Je-Kang Du
Journal:  J Dent Sci       Date:  2020-12-31       Impact factor: 2.080

5.  Effect of Intermediate Agents and Preheated Composites on Repair Bond Strength of Silorane-Based Composites.

Authors:  Fereshteh Shafiei; Sahar Akbarian; Marzieh Daryadar
Journal:  J Dent (Tehran)       Date:  2015-09
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.