Literature DB >> 23110580

Two-year clinical performance of self-etching adhesive systems in composite restorations of anterior teeth.

D C Barcellos1, G R Batista, M A Silva, P R Pleffken, P M Rangel, V V B Fernandes, R Di Nicoló, C R G Torres.   

Abstract

OBJECTIVE: The aim of this study was to evaluate the two-year clinical performance of Class III, IV, and V composite restorations using a two-step etch-and-rinse adhesive system (2-ERA) and three one-step self-etching adhesive systems (1-SEAs).
MATERIAL AND METHODS: Two hundred Class III, IV, and V composite restorations were placed into 50 patients. Each patient received four composite restorations (Amaris, Voco), and these restorations were bonded with one of three 1-SEAs (Futurabond M, Voco; Clearfil S3 Bond, Kuraray; and Optibond All-in-One, Kerr) or one 2-ERA (Adper Single Bond 2/3M ESPE). The four adhesive systems were evaluated at baseline and after 24 months using the following criteria: restoration retention, marginal integrity, marginal discoloration, caries occurrence, postoperative sensitivity and preservation of tooth vitality. After two years, 162 restorations were evaluated in 41 patients. Data were analyzed using the χ(2) test (p<0.05).
RESULTS: There were no statistically significant differences between the 2-ERA and the 1-SEAs regarding the evaluated parameters (p>0.05).
CONCLUSION: The 1-SEAs showed good clinical performance at the end of 24 months.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23110580     DOI: 10.2341/11-397-C

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  1 in total

1.  Five-year clinical performance of a HEMA-free one-step self-etch adhesive in noncarious cervical lesions.

Authors:  Kirsten L Van Landuyt; Jan De Munck; R Banu Ermis; Marleen Peumans; Bart Van Meerbeek
Journal:  Clin Oral Investig       Date:  2013-08-15       Impact factor: 3.573

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.