Literature DB >> 23110305

Influence of platform and abutment angulation on peri-implant bone. A three-dimensional finite element stress analysis.

Ana Paula Martini1, Rosália Moreira Barros, Amilcar Chagas Freitas Júnior, Eduardo Passos Rocha, Erika Oliveira de Almeida, Cacilda Cunha Ferraz, Maria Cristina Jimenez Pellegrin, Rodolfo Bruniera Anchieta.   

Abstract

The aim of this study was to evaluate stress distribution on the peri-implant bone, simulating the influence of Nobel Select implants with straight or angulated abutments on regular and switching platform in the anterior maxilla, by means of 3-dimensional finite element analysis. Four mathematical models of a central incisor supported by external hexagon implant (13 mm × 5 mm) were created varying the platform (R, regular or S, switching) and the abutments (S, straight or A, angulated 15°). The models were created by using Mimics 13 and Solid Works 2010 software programs. The numerical analysis was performed using ANSYS Workbench 10.0. Oblique forces (100 N) were applied to the palatine surface of the central incisor. The bone/implant interface was considered perfectly integrated. Maximum (σmax) and minimum (σmin) principal stress values were obtained. For the cortical bone the highest stress values (σmax) were observed in the RA (regular platform and angulated abutment, 51 MPa), followed by SA (platform switching and angulated abutment, 44.8 MPa), RS (regular platform and straight abutment, 38.6 MPa) and SS (platform switching and straight abutment, 36.5 MPa). For the trabecular bone, the highest stress values (σmax) were observed in the RA (6.55 MPa), followed by RS (5.88 MPa), SA (5.60 MPa), and SS (4.82 MPa). The regular platform generated higher stress in the cervical periimplant region on the cortical and trabecular bone than the platform switching, irrespective of the abutment used (straight or angulated).

Entities:  

Mesh:

Year:  2012        PMID: 23110305     DOI: 10.1563/AAID-JOI-D-11-00029

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  6 in total

1.  Platform switching vs standard implants in partially edentulous patients using the Dental Tech Implant System: clinical and radiological results from a prospective multicenter study.

Authors:  Massimo Del Fabbro; Carlo Bianchessi; Riccardo Del Lupo; Luca Landi; Silvio Taschieri; Stefano Corbella
Journal:  Clin Oral Investig       Date:  2015-03-31       Impact factor: 3.573

2.  Dental implant primary stability in different regions of the Jawbone: CBCT-based 3D finite element analysis.

Authors:  Razan Alaqeely; Nadir Babay; Montaser AlQutub
Journal:  Saudi Dent J       Date:  2019-06-17

3.  The importance of correct implants positioning and masticatory load direction on a fixed prosthesis.

Authors:  João-Paulo-Mendes Tribst; Vinicius-Aneas Rodrigues; Amanda-Maria-de Oliveira Dal Piva; Alexandre-Luiz-Souto Borges; Renato-Sussumu Nishioka
Journal:  J Clin Exp Dent       Date:  2018-01-01

4.  Evaluation of Stress Generated with Different Abutment Materials and Angulations under Axial and Oblique Loading in the Anterior Maxilla: Three-Dimensional Finite Element Analysis.

Authors:  Sumedha Kapoor; Shobha Rodrigues; M Mahesh; Thilak Shetty; Umesh Pai; Sharon Saldanha; Puneeth Hedge; Satish Shenoy
Journal:  Int J Dent       Date:  2021-12-01

5.  The Effect of Abutment Angulation and Crown Material Compositions on Stress Distribution in 3-Unit Fixed Implant-Supported Prostheses: A Finite Element Analysis.

Authors:  Ramin Mosharraf; Mahsa Abbasi; Pirooz Givehchian
Journal:  Int J Dent       Date:  2022-08-27

6.  Effects of crown retrieval on implants and the surrounding bone: a finite element analysis.

Authors:  Serhat Emre Ozkir; Server Mutluay Unal; Emel Yurekli; Sedat Güven
Journal:  J Adv Prosthodont       Date:  2016-04-21       Impact factor: 1.904

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.