Literature DB >> 23109290

Accelerated high-frame-rate mouse heart cine-MRI using compressed sensing reconstruction.

Abdallah G Motaal1, Bram F Coolen, Desiree Abdurrachim, Rui M Castro, Jeanine J Prompers, Luc M J Florack, Klaas Nicolay, Gustav J Strijkers.   

Abstract

We introduce a new protocol to obtain very high-frame-rate cinematographic (Cine) MRI movies of the beating mouse heart within a reasonable measurement time. The method is based on a self-gated accelerated fast low-angle shot (FLASH) acquisition and compressed sensing reconstruction. Key to our approach is that we exploit the stochastic nature of the retrospective triggering acquisition scheme to produce an undersampled and random k-t space filling that allows for compressed sensing reconstruction and acceleration. As a standard, a self-gated FLASH sequence with a total acquisition time of 10 min was used to produce single-slice Cine movies of seven mouse hearts with 90 frames per cardiac cycle. Two times (2×) and three times (3×) k-t space undersampled Cine movies were produced from 2.5- and 1.5-min data acquisitions, respectively. The accelerated 90-frame Cine movies of mouse hearts were successfully reconstructed with a compressed sensing algorithm. The movies had high image quality and the undersampling artifacts were effectively removed. Left ventricular functional parameters, i.e. end-systolic and end-diastolic lumen surface areas and early-to-late filling rate ratio as a parameter to evaluate diastolic function, derived from the standard and accelerated Cine movies, were nearly identical.
Copyright © 2012 John Wiley & Sons, Ltd.

Entities:  

Keywords:  Cine MRI; compressed sensing; diastolic function; heart; mouse

Mesh:

Year:  2012        PMID: 23109290     DOI: 10.1002/nbm.2883

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  3 in total

1.  Functional imaging of murine hearts using accelerated self-gated UTE cine MRI.

Authors:  Abdallah G Motaal; Nils Noorman; Wolter L de Graaf; Verena Hoerr; Luc M J Florack; Klaas Nicolay; Gustav J Strijkers
Journal:  Int J Cardiovasc Imaging       Date:  2014-09-10       Impact factor: 2.357

2.  Comparison of total variation with a motion estimation based compressed sensing approach for self-gated cardiac cine MRI in small animal studies.

Authors:  Juan F P J Abascal; Paula Montesinos; Eugenio Marinetto; Javier Pascau; Manuel Desco
Journal:  PLoS One       Date:  2014-10-28       Impact factor: 3.240

3.  Exploration of New Contrasts, Targets, and MR Imaging and Spectroscopy Techniques for Neuromuscular Disease - A Workshop Report of Working Group 3 of the Biomedicine and Molecular Biosciences COST Action BM1304 MYO-MRI.

Authors:  Gustav J Strijkers; Ericky C A Araujo; Noura Azzabou; David Bendahan; Andrew Blamire; Jedrek Burakiewicz; Pierre G Carlier; Bruce Damon; Xeni Deligianni; Martijn Froeling; Arend Heerschap; Kieren G Hollingsworth; Melissa T Hooijmans; Dimitrios C Karampinos; George Loudos; Guillaume Madelin; Benjamin Marty; Armin M Nagel; Aart J Nederveen; Jules L Nelissen; Francesco Santini; Olivier Scheidegger; Fritz Schick; Christopher Sinclair; Ralph Sinkus; Paulo L de Sousa; Volker Straub; Glenn Walter; Hermien E Kan
Journal:  J Neuromuscul Dis       Date:  2019
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.