Literature DB >> 23109043

Study on effects of partial ossicular replacement prostheses with different materials on hearing restoration.

Wenjuan Yao1, Cuiping Guo, Xuemei Luo.   

Abstract

Numerical simulation method was used in this paper to study the effects of partial ossicular replacement prostheses (PORPs) with different materials on hearing restoration, from the biomechanical point of view. According to the CT scan imagery of the right ear from a normal human body, the CT data was digitalized and imported into PATRAN to establish a three dimension finite element model by self-compiling program, and then a frequency response analysis was made for the model. The calculated results were compared with experiment data to verify the correctness of the numerical model. Based on this, human numerical model of PORPs was established to make dynamic calculation of sound conduction and analyse the effects of PORPs with different materials on hearing restoration. The following conclusions are obtained : From the angle of dynamical behaviors in sound conduction process of human ear, in different frequency bands of the same sound pressure, PORPs with different materials have different effects on hearing restoration. A better sound transmission in low frequencies is obtained by PORPs with hydroxyapatite ceramics, stainless steel. In high frequencies, better sound transmission is gained by PORPs with porous polyethylene. In the 500-3,000 Hz range which is clinicians typically measure and pay attention to, better sound transmission is gained by PORPs with alumina ceramics, hydroxyapatite ceramics, EH composite materials and porous polyethylene. There are three materials which has an obvious potential to provide more hearing restoration than another between 500 and 3,000 Hz. The hearing restoration value of hydroxyapatite ceramics is 7.1 dB larger than that of stainless steel. The hearing restoration value of titanium is 4.9 dB larger than that of stainless steel. Hydroxyapatite ceramics has better effects on sound transmission than titanium and other materials.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23109043     DOI: 10.1007/s10856-012-4800-6

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  8 in total

1.  Middle-ear dynamics before and after ossicular replacement.

Authors:  P Ferris; P J Prendergast
Journal:  J Biomech       Date:  2000-05       Impact factor: 2.712

2.  Malleus-to-footplate prosthetic interposition: experience with 265 patients.

Authors:  V Colletti; F G Fiorino
Journal:  Otolaryngol Head Neck Surg       Date:  1999-03       Impact factor: 3.497

3.  The effect of prosthesis design on vibration of the reconstructed ossicular chain: a comparative finite element analysis of four prostheses.

Authors:  D J Kelly; P J Prendergast; A W Blayney
Journal:  Otol Neurotol       Date:  2003-01       Impact factor: 2.311

4.  Hydroxylapatite ossicular replacement prostheses: a four-year experience.

Authors:  R A Goldenberg
Journal:  Otolaryngol Head Neck Surg       Date:  1992-03       Impact factor: 3.497

5.  Three-dimensional finite element modeling of human ear for sound transmission.

Authors:  Rong Z Gan; Bin Feng; Qunli Sun
Journal:  Ann Biomed Eng       Date:  2004-06       Impact factor: 3.934

6.  Acoustic-structural coupled finite element analysis for sound transmission in human ear--pressure distributions.

Authors:  Rong Z Gan; Qunli Sun; Bin Feng; Mark W Wood
Journal:  Med Eng Phys       Date:  2005-08-24       Impact factor: 2.242

7.  Modeling of sound transmission from ear canal to cochlea.

Authors:  Rong Z Gan; Brian P Reeves; Xuelin Wang
Journal:  Ann Biomed Eng       Date:  2007-09-18       Impact factor: 3.934

8.  Hearing results with the Dornhoffer ossicular replacement prostheses.

Authors:  J L Dornhoffer
Journal:  Laryngoscope       Date:  1998-04       Impact factor: 3.325

  8 in total