Reduced contrast medium in abdominal aorta CTA using a multiphasic injection technique.

Wouter H Nijhof1, Charlotte S van der Vos, Bauke Anninga, Paulien L Stegehuis, Gerrit J Jager, Matthieu J C M Rutten.   

Abstract

PURPOSE: The purpose of this study was to determine if with a multiphasic injection technique the administered amount of contrast medium for abdominal computerized tomographic angiography (CTA) can be decreased, whilst improving CT image quality.
MATERIALS AND METHODS: In 30 patients a multiphasic injection method was compared to the standard uniphasic contrast medium injection protocol. Fifteen patients underwent abdominal CTA with a standard uniphasic injection protocol (protocol I) receiving 100mL of a non-ionic radiopaque contrast agent (Ioversol). The second group of 15 patients underwent CTA with a multiphasic injection protocol (protocol II) receiving a total of 89 mL Ioversol. Vascular contrast enhancement and difference in enhancement uniformity were assessed quantitatively and image quality was assessed by three independent radiologists.
RESULTS: Quantitative assessment of the vascular contrast enhancement showed that there was no significant difference in enhancement uniformity for patients between the protocols. The image quality was rated as being good to excellent in 81.8% and 88.0% of the scans, for protocol I and protocol II, respectively. However these differences were not statistically significant.
CONCLUSION: By using a multiphasic injection technique with CTA of the abdominal aorta a reduction of 11 percent of contrast medium can be realized. Enhancement patterns are quantitatively as well as qualitatively comparable to the standard contrast medium injection protocol.
Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23107171     DOI: 10.1016/j.ejrad.2012.09.022

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  2 in total

1.  Contrast Volume for Preoperative CT Angiography of the Aorta Based on Patient Heart Rate and Body Surface Area: A Pilot Study.

Authors:  Dominic Raymakers; Adriana Dubbeldam; Walter Coudyzer; Hilde Bosmans; Geert Maleux
Journal:  J Belg Soc Radiol       Date:  2019-10-04       Impact factor: 1.894

2.  Feasibility of low contrast media volume in CT angiography of the aorta.

Authors:  Anna Seehofnerová; Madeleine Kok; Casper Mihl; Dave Douwes; Anni Sailer; Estelle Nijssen; Michiel J W de Haan; Joachim E Wildberger; Marco Das
Journal:  Eur J Radiol Open       Date:  2015-04-28
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.