Literature DB >> 23106879

Efficacy and safety of bipolar plasma vaporization of the prostate with "button-type" electrode compared with transurethral resection of prostate for benign prostatic hyperplasia.

Shi-Ying Zhang1, Hao Hu, Xiao-Peng Zhang, Dong Wang, Ke-Xin Xu, Yan-Qun Na, Xiao-Bo Huang, Xiao-Feng Wang.   

Abstract

BACKGROUND: Transurethral resection of prostate (TURP) has been considered as the standard treatment for benign prostatic hyperplasia (BPH). However, issues that have not yet been overcome for TURP include bleeding and absorption of irrigation fluid. Thus, novel improvement of the surgery is necessary. This study aimed to evaluate the efficacy and safety of bipolar plasma vaporization of the prostate (BPVP) with "button-type" electrode against standard TURP for BPH.
METHODS: From January 2009 to January 2012, 30 patients who scheduled for surgical treatment of BPH surgical treatment were enrolled in the trial with provided consent for the study. Patients were prospectively randomized 1:1 to undergo either BPVP or TURP. Participants were blinded to the randomization scheme. All cases were assessed preoperatively and followed at 1, 3, and 6 months postoperatively by indwelling catheter time, blood loss, hospital stays, International Prostate Symptom Score (IPSS), quality of life (QOL), and Qmax.
RESULTS: BPVP was significantly superior to TURP in terms of indwelling catheter time ((4.1 ± 4.1) days vs. (6.8 ± 6.8) days, P = 0.000), blood loss ((64.7 ± 103.8) ml vs. (254.7 ± 325.4) ml, P = 0.040), hospital stay ((8.7 ± 1.0) days vs. (11.7 ± 1.5) days, P = 0.000), IPSS ((4.2 ± 8.0) vs. (9.3 ± 3.7), P = 0.049), QOL ((1.5 ± 0.8) vs. (2.6 ± 1.4), P = 0.027), Qmax ((16.3 ± 5.7) ml/s vs. (12.5 ± 3.1) ml/s, P = 0.038), hemoglobin ((130.7 ± 9.4) g/L vs. ((122.1 ± 11.9) g/L, P = 0.047), Na(+) level ((138.6 ± 2.1) mmol/L vs. ((137.2 ± 2.0) mmol/L, P = 0.046) and operation time ((39.0 ± 15.5) minutes vs. ((69.3 ± 24.8) minutes, P = 0.004). And there were no statistical differences between BPVP group and TURP group in preoperatively assessment: patient's age ((70.9 ± 7.1) years vs. (71.9 ± 6.1) years, P = 0.736), IPSS ((24.6 ± 4.7) vs. (27.3 ± 5.9), P = 0.100), QOL ((5.1 ± 0.8) vs. (5.1 ± 1.0), P = 0.940), Qmax ((4.4 ± 2.7) ml/s vs. (5.3 ± 2.6) ml/s, P = 0.314), hemoglobin ((137.4 ± 8.7) g/L vs. (139.2 ± 10.4) g/L, P = 0.623), Na(+) level ((140.5 ± 1.8) mmol/L vs. (141.3 ± 1.4) mmol/L, P = 0.192) and prostate volume ((59.0 ± 17.4) ml vs. (70.1 ± 28.8) ml, P = 0.276).
CONCLUSIONS: Compared with TURP, BPVP with "button-type" electrode shows superior efficacy and safety. Therefore, BPVP with "button-type" electrode represents a valuable endoscopic treatment alternative for BPH patients.

Entities:  

Mesh:

Year:  2012        PMID: 23106879

Source DB:  PubMed          Journal:  Chin Med J (Engl)        ISSN: 0366-6999            Impact factor:   2.628


  14 in total

1.  Comparison of outpatient versus inpatient transurethral prostate resection for benign prostatic hyperplasia: Comparative, prospective bi-centre study.

Authors:  Jae Heon Kim; Jae Young Park; Ji Sung Shim; Jeong Gu Lee; Du Geon Moon; Jeong Woo Yoo; Hoon Choi; Jae Hyun Bae
Journal:  Can Urol Assoc J       Date:  2014 Jan-Feb       Impact factor: 1.862

Review 2.  Bipolar plasma vaporization of the prostate: ready to replace GreenLight? A systematic review of randomized control trials.

Authors:  Grégoire Robert; Alexandre de la Taille; Thomas Herrmann
Journal:  World J Urol       Date:  2014-08-27       Impact factor: 4.226

Review 3.  [Surgical treatment of benign prostatic hyperplasia-resection, vaporization or enucleation?]

Authors:  M Rieken; T R W Herrmann; C Füllhase
Journal:  Urologe A       Date:  2019-03       Impact factor: 0.639

4.  Reasons to believe in vaporization: a review of the benefits of photo-selective and transurethral vaporization.

Authors:  Russell N Schwartz; Felix Couture; Iman Sadri; Adel Arezki; David-Dan Nguyen; Ahmed S Zakaria; Kyle Law; Dean Elterman; Malte Rieken; Hannes Cash; Kevin C Zorn
Journal:  World J Urol       Date:  2020-09-15       Impact factor: 4.226

5.  Prostate volume reduction following pure transurethral bipolar plasma vaporization and conventional transurethral resection of the prostate: a prospective investigation using transrectal 3D ultrasound volumetry.

Authors:  Benedikt Kranzbühler; Oliver Gross; Christian D Fankhauser; Marian S Wettstein; Nico C Grossmann; Lukas J Hefermehl; Matthias Zimmermann; Alexander Müller; Daniel Eberli; Tullio Sulser; Cédric Poyet; Thomas Hermanns
Journal:  World J Urol       Date:  2016-06-23       Impact factor: 4.226

6.  Comparison of Safety, Efficacy and Cost Effectiveness of Photoselective Vaporization with Bipolar Vaporization of Prostate in Benign Prostatic Hyperplasia.

Authors:  Priyanka Rai; Alok Srivastava; Ishwar R Dhayal; Sanjeet Singh
Journal:  Curr Urol       Date:  2017-12-30

7.  Bipolar button-electrode plasma vaporization of the prostate: An effective option for patients with post-brachytherapy retention.

Authors:  Yiwei Lin; Ben Liu; Liping Xie
Journal:  Exp Ther Med       Date:  2015-08-05       Impact factor: 2.447

8.  Efficacy and safety of 120-W thulium:yttrium-aluminum-garnet vapoenucleation of prostates compared with holmium laser enucleation of prostates for benign prostatic hyperplasia.

Authors:  Kai Hong; Yu-Qing Liu; Jian Lu; Chun-Lei Xiao; Yi Huang; Lu-Lin Ma
Journal:  Chin Med J (Engl)       Date:  2015-04-05       Impact factor: 2.628

9.  Efficacy of bipolar "button" plasma vaporization of the prostate for benign prostatic obstruction, compared to the standard technique.

Authors:  Hamdy Aboutaleb
Journal:  Urol Ann       Date:  2015 Oct-Dec

Review 10.  Low temperature plasma: a novel focal therapy for localized prostate cancer?

Authors:  Adam M Hirst; Fiona M Frame; Norman J Maitland; Deborah O'Connell
Journal:  Biomed Res Int       Date:  2014-03-13       Impact factor: 3.411

View more