Literature DB >> 23105313

Serum proteins analysis by capillary electrophoresis.

Y Uji1, H Okabe.   

Abstract

The purpose of this study was to evaluate the efficacy of multi-capillary electrophoresis instrument in clinical laboratory. An automated clinical capillary electrophoresis system was evaluated for performing serum proteins electrophoresis and immuno-fixation electrophoresis by subtraction. In this study the performance of capillary electrophoresis was compared with the cellulose acetate membrane electrophoresis and agarose gel immunofixation electrophoresis for serum proteins. The results of capillary electrophoresis and cellulose acetate membrane electrophoresis were good (r=0.89∼0.97) for protein fractions and A/G ratio except for β-gobulin fraction (r=0.60). Both within-run and day to day precisions (CVs) of assay results for 5 main fractions and A/G ratio (n=10) were between 0.3∼6.3%. The reference ranges of serum protein fractions obtained from 200 healthy individuals by cellulose acetate membrane electrophoresis were almost equal to that of capillary electrophoresis except for α-1 globulin fraction. No significant difference of electropherograms between cellulose acetate electrophoresis and capillary electrophoresis was observed in the abnormal serum such as presence of bilirubin (<20mg/dl), hemoglobin (<300 mg/dl), lipid (Intralipos <1%) and samples from patients with acute phase response, liver injury, polyclonal hyper gammaglobulinemia or M-proteinemia. The method of capillary immuno-fixation electrophoresis by subtraction showed good agreement with agarose gel immunofixation electrophoresis by subtraction identifying 30 monoclonal gammmopathy patient samples.

Entities:  

Keywords:  Capillary electrophoresis; M-protein; capillary immunofixation electrophoresis; serum proteins

Year:  2001        PMID: 23105313      PMCID: PMC3453640          DOI: 10.1007/BF02864856

Source DB:  PubMed          Journal:  Indian J Clin Biochem        ISSN: 0970-1915


  5 in total

1.  Capillary electrophoresis--a new clinical tool.

Authors:  F T Chen; C M Liu; Y Z Hsieh; J C Sternberg
Journal:  Clin Chem       Date:  1991-01       Impact factor: 8.327

Review 2.  Consensus of a group of professional societies and diagnostic companies on guidelines for interim reference ranges for 14 proteins in serum based on the standardization against the IFCC/BCR/CAP Reference Material (CRM 470). International Federation of Clinical Chemistry. Community Bureau of Reference of the Commission of the European Communities. College of American Pathologists.

Authors:  F Dati; G Schumann; L Thomas; F Aguzzi; S Baudner; J Bienvenu; O Blaabjerg; S Blirup-Jensen; A Carlström; P H Petersen; A M Johnson; A Milford-Ward; R F Ritchie; P J Svendsen; J Whicher
Journal:  Eur J Clin Chem Clin Biochem       Date:  1996-06

3.  Agarose gel electrophoresis.

Authors:  J O Jeppsson; C B Laurell; B Franzén
Journal:  Clin Chem       Date:  1979-04       Impact factor: 8.327

4.  Imprecision of protein electrophoresis.

Authors:  J D Baars; A J Lombarts
Journal:  Clin Chem       Date:  1986-07       Impact factor: 8.327

5.  Characterization of small monoclonal protein bands with Beckman's "Paragon" immunofixation system.

Authors:  S Y Chu; J E MacLeod; L Bocci; M Monteith
Journal:  Clin Chem       Date:  1987-04       Impact factor: 8.327

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.