Literature DB >> 23105234

A rapid method for plasma ammonia estimation using an indigenously purified enzyme.

M A Qadar Pasha1, R B Ram, M D Gupta.   

Abstract

Determination of ammonia level in blood is important, especially in the diagnosis of hepatic disorders. An indigenously purified enzyme was used in the standardisation of the assay. The assay is a two reagent system, requires five minutes for completion and can be performed at temperature between 25-27°C. Performance of the assay was assessed by linearity, imprecision, functional sensitivity and interference studies. Lyophilised reagent I and reagent II were found stable for at least one year. The plasma level of ammonia for the controls was 13.7±7.3 μMol/L, whereas for subjects of hepatic disorders, it was 69.1±32.4 μMol/L (P<0.001). The functional sensitivity was between 2-1000 μMol/L. Within-run coefficient of variation was between 1.1-2.0% and between-run coefficient of variation was between 1.9-3.7%. The mean recovery after dilution was 99.6%. The present method can estimate ammonia up to 1000 μMol/L without dilution of sample. Assay time of five minute may be shortened to one minute. This method is suited for routine clinical use in treatment of hepatic disorders.

Entities:  

Keywords:  Ammonia; deaminase inhibitor; enzymatic assay; glutamate dehydrogenase

Year:  2000        PMID: 23105234      PMCID: PMC3453541          DOI: 10.1007/BF02873544

Source DB:  PubMed          Journal:  Indian J Clin Biochem        ISSN: 0970-1915


  8 in total

1.  Which is the appropriate coenzyme for the measurement of ammonia with glutamate dehydrogenase?

Authors:  F da Fonseca-Wollheim; K G Heinze
Journal:  Eur J Clin Chem Clin Biochem       Date:  1992-09

2.  Determination of ammonia in blood plasma by an ion exchange method.

Authors:  K Kurahasi; A Ishihara; H Uehara
Journal:  Clin Chim Acta       Date:  1972-11       Impact factor: 3.786

3.  Reference intervals for blood ammonia in healthy subjects, determined by microdiffusion.

Authors:  J Diaz; P L Tornel; P Martinez
Journal:  Clin Chem       Date:  1995-07       Impact factor: 8.327

4.  Effect of temperature, duration of storage and sampling procedure on ammonia concentration in equine blood plasma.

Authors:  A Lindner; S Bauer
Journal:  Eur J Clin Chem Clin Biochem       Date:  1993-07

Review 5.  Determination of ammonia in biological fluids.

Authors:  J R Huizenga; A Tangerman; C H Gips
Journal:  Ann Clin Biochem       Date:  1994-11       Impact factor: 2.057

6.  Enzymatic determination of plasma ammonia: evaluation of Sigma and BMC Kits.

Authors:  M Pesh-Imam; S Kumar; C E Willis
Journal:  Clin Chem       Date:  1978-11       Impact factor: 8.327

7.  A kinetic determination of ammonia in plasma.

Authors:  H C van Anken; M E Schiphorst
Journal:  Clin Chim Acta       Date:  1974-10-30       Impact factor: 3.786

8.  Influences of specimen processing and storage conditions on results for plasma ammonia.

Authors:  J H Howanitz; P J Howanitz; C A Skrodzki; J A Iwanski
Journal:  Clin Chem       Date:  1984-06       Impact factor: 8.327

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.