Literature DB >> 23104314

Enhancement of biological mass spectrometry by using separations based on changes in ion mobility (FAIMS and DMS).

Randy W Purves1.   

Abstract

Analysis of complex biological samples for low-level analytes by liquid chromatography-tandem mass spectrometry (LC-MS/MS) often requires additional selectivity. Differential mobility techniques (FAIMS and DMS) have been shown to enhance LC-MS/MS analyses by separating ions in the gas-phase on a millisecond timescale by use of a mechanism that is complementary to both liquid chromatography and mass spectrometry. In this overview, a simplified description of the operation of these devices is given and an example presented that illustrates the utility of FAIMS (DMS) for solving a challenging analytical assay. Important recent advances in the field, including work with gas modifiers, are presented, along with an outlook for the technology.

Mesh:

Substances:

Year:  2012        PMID: 23104314     DOI: 10.1007/s00216-012-6496-3

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  5 in total

1.  Optimization of a New Aerodynamic Cylindrical FAIMS Device for Small Molecule Analysis.

Authors:  Randy W Purves; Satendra Prasad; Michael Belford; Albert Vandenberg; Jean-Jacques Dunyach
Journal:  J Am Soc Mass Spectrom       Date:  2017-01-17       Impact factor: 3.109

2.  Correlating Resolving Power, Resolution, and Collision Cross Section: Unifying Cross-Platform Assessment of Separation Efficiency in Ion Mobility Spectrometry.

Authors:  James N Dodds; Jody C May; John A McLean
Journal:  Anal Chem       Date:  2017-10-30       Impact factor: 6.986

3.  Rapid Separation and Quantitation of Cocaine and its Metabolites in Human Serum by Differential Mobility Spectrometry-tandem Mass Spectrometry (DMS-MS-MS).

Authors:  Sara K Dempsey; F Gerard Moeller; Justin L Poklis
Journal:  J Anal Toxicol       Date:  2018-10-01       Impact factor: 3.367

4.  A needle-to-post air discharge ion source in tandem with FAIMS system.

Authors:  Hua Li; Hongmei Yun; Yongrong Jiang; Ruosheng Zeng; Zhencheng Chen
Journal:  PLoS One       Date:  2019-08-16       Impact factor: 3.240

5.  Development of a high-throughput differential mobility separation-tandem mass spectrometry (DMS-MS/MS) method for clinical urine drug testing.

Authors:  Shirin Hooshfar; Simone Tchu; Cassandra Yun; Kara L Lynch
Journal:  J Mass Spectrom Adv Clin Lab       Date:  2022-01-03
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.